Problem
Cause
The motor is not
• The switch is off.
starting.
• Not enough fuel.
• The oil level is very low or is has no oil.
• Appliances connected to the machine.
• Gasoline is not reaching the carburetor.
• There is no spark in the spark plug.
The motor starts but
• Oil level is too low.
stops unexpectedly.
There is no power in
• The overload thermal protector has not been
the connection panel
re-established.
outputs.
• Some of the appliances are not working.
The machine has no
voltage.
• Damaged thermal protector.
There is no arc onset
• The switch is in the OFF position.
or is difficult to light
• Partial short circuit in the motor winding.
the arch after the
welder in on.
If the problems persist despite carrying out the recommended corrective actions,
contact a
Solution
• Turn on the switch.
• Fill up the fuel tank.
• Check motor oil level as indicated in page 9.
• Disconnect all the appliances from the
connection panel before starting the machine's
motor.
• With the full fuel tank verify the flow of fuel in
the carburetor:
1. Set under the carburetor an adequate
container to receive gasoline and use a funnel to
prevent fuel spills.
2. Remove the drain bolt. Fuel shall flow freely.
Otherwise go to a
zed Service Center.
• Verify the spark in the spark plug:
1. Disconnect the spark plug cable, clean dust
around the spark plug and remove it.
2. Connect the cable to the spark plug.
3. Turn on the motor switch.
4. Make contact with the spark plug side
electrode into any metallic and free of oil part in
the motor.
CAUTION
make this test in ventilated areas and with no fuel
spillage. Otherwise, an explosion can occur.
5. Pull the starter handle to generate a spark
between the spark plug central electrode and the
metallic part. If there is no spark replace the
spark plug.
6. If there is no spark with the new spark plug go
to a
Center.
• Check the motor oil level as indicated in page 9.
Restart the motor again.
• Verify the overload thermal protector is ON.
• Check the appliances before connecting. Repair
any damaged appliance before plugging into the
machine.
• Go to a
Center to replace it.
• Set the switch in the ON position.
• Go to a
Center to repair the machine.
Authorized Service Center
Authori-
It is important to
Authorized Service
Authorized Service
Authorized Service