Spare Parts; Electrical Diagram; Disposal; Ce Declaration - PLYMOVENT MOBILEGO Manual De Instalación Y De Uso

Aspirador fijo para humos de soldadura con dos brazos fle
Ocultar thumbs Ver también para MOBILEGO:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 35
Symptom
Problem
The fan does
The unit does
not start
not function
The green
The unit does
LED is on but
not function
the fan does
not run
Poor
The unit does
extraction
not function
capacity
properly
The buzzer
Poor
emits an
extraction
acoustic
capacity
signal
The
Escape of
extraction
fume; no
arm does not
proper
stay in the
extraction
desired
position
You cannot
get the arm
in the desired
position
8

SPaRE PaRTS

8.1
Filter unit
The following spare filters are available for the filter unit;
- refer to exploded view Fig. VIII on page 57
8.2
Extraction arm
The following spare parts are available for the extraction arms;
- hose tube arm (EconomyArm): refer to exploded view Fig. VI
on page 53
0000111659/150418/B MobileGo
Possible
Solution
cause
No mains
Connect the mains
voltage
voltage
Thermal
- Examine the fan
overload
and motor to find
protection is
the cause and
activated
remedy the
problem
- Push the red
button behind the
front panel to
reset. Refer to
Fig. IV on page
51
The mains cord
Repair or replace
is defective
the mains cord
Loose contacts
Repair the contacts
Motor defective
Repair or replace
the motor
Relay is
Replace the relay
defective
Thermal relay is
Replace the thermal
defective
relay
Motor defective
Repair or replace
the motor
The shut-off
(Fully) open the
damper in the
shut-off damper
hood of the
extraction arm
is (partly)
closed
Clogged filters
Repair the
& loose
connection of the
connection of
pressure tubes
pressure sensor
Clogged filters
Replace the
& defective
pressure sensor &
pressure sensor
the pre filter
cassette
Replace the HEPA
filter cassette as
well
The pre filter is
Replace the pre
clogged
filter cassette
The HEPA filter
Replace the HEPA
is clogged
filter cassette
Friction setting
Adjust the friction;
is not correct
refer to Fig. V on
page 52 for the
adjustment points
- metal tube arm (KUA): refer to exploded view Fig. VII on
page 55
9

ELECTRiCaL DiaGRaM

Refer to the separately supplied electrical diagram.
10

DiSPoSaL

Dismantling and disposal of the unit must be done by qualified
persons.
Personal protective equipment (PPE)
Wear respiratory protection and protective
gloves when you dismantle and dispose of
the unit.
10.1
Dismantling
To safely dismantle the unit, obey the safety instructions that
follow.
Before dismantling of the unit:
- disconnect it from the mains
- clean the outside
During dismantling of the unit:
- make sure that the area is sufficiently ventilated, e.g. by a
mobile ventilation unit
After dismantling of the unit:
- clean the dismantling area
10.2
Disposal
Dispose of the pollutants and dust, together with the used
filters, in a professional manner in accordance with federal,
state or local regulations.

CE DECLaRaTioN

CE declaration of conformity for machinery
We, Plymovent Manufacturing B.V., Koraalstraat 9, 1812 RK
Alkmaar, Netherlands, herewith declare, on our own
responsibility, that the products:
- MobileGo
- MobileGo
plus
which this declaration refers to, are in accordance with the
conditions of the following Directives:
- Machine Directive 2006/42 EC
- EMC 2014/30 EU
- LVD 2014/35 EU
- ErP Directive 2009/125 EC
Signature:
Name:
M.S.J. Ligthart
Position:
Product Manager
Date of issue:
1st May 2018
EN - 9

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Mobilegoplus

Tabla de contenido