Technical Information
6. T
I
ECHNICAL
Product
Maintenance
7. T
S
ECHNICAL
Dimensions and Weight
Power
Light Source
Photo Optic
Thermal
External Controller
Ordering
NFORMATION
Dust build-up reduces light output performance and can cause overheating. To maintain optimum
performance, clean the product at least twice a month. Note: Use and environmental conditions may
contribute to increasing the cleaning frequency.
To clean the product, follow the instructions below:
•
Unplug the product from power.
•
Wait until the product is cold.
•
Use a vacuum (or dry compressed air) and a soft brush to remove dust collected on the external
surface/vents.
•
Clean the glass surfaces with a mild soap solution, ammonia-free glass cleaner, or isopropyl
alcohol.
•
Apply the solution directly to a soft, lint-free cotton cloth or a lens cleaning tissue.
•
Softly wipe any dirt or grime to the outside edges of the glass surface.
•
Gently polish the glass surfaces until they are free of haze and lint.
Always dry the glass surfaces carefully after cleaning them.
Do not spin the cooling fan using compressed air because you could damage it.
PECIFICATIONS
Length
278 mm
Power Supply Type
Switching (internal)
Parameter
Consumption
Operating
Fuse
Power I/O
Power Cord plug
Type
Class 3B Laser Diodes
Quantity/Color
1/Red
1/Green
1/Blue
Parameter
Zoom angle
Maximum External Temp.
104° F (40° C)
I/O Connectors
(DMX) 3-pin XLR
(ILDA) DB25
Product Name
Scorpion Scan 3D EU
Width
290 mm
Range
100~240 V, 50/60 Hz
230 V, 50 Hz
50 W
0.2 A
T1A, 250 V
UK/Europe
Local plug
Power
Varied (see below)
Power
100 mW
80 mW
300 mW
1~36º
Cooling System
Fan
Connector Type
Sockets
Serial
Item Code
10060537
Page 14 of 44
Height
Weight
202 mm
4.2 kg
Voltage Selection
Auto-ranging
Wavelength
638 nm
532 nm
450 nm
Scanner Speed
25k
Channel Range
1~19
1~2
UPC Code
781462208851