Fire Input; Installation Of The Optical Safety Edge; Timer Function; Clock Function - V2 EASY Manual Del Usuario

Cuadro de maniobras analógico para toldos y puertas basculantes
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

FIRE INPUT

Safety input for the connection of a fire alarm or another type of
alarm requiring the immediate automatic opening of the door.
When the contact FIRE opens, the doors opens and it is not
possible to close it until the contact is restored.
INSTALLATION OF THE OPTICAL SAFETY
EDGE
The control unit EASY-CRI is preset for the installation of an
optical safety edge with 24V direct current power supply and
adjustment of the power of the transmitter.
WARNING: use only FEEL optical safety edges (see V2
catalogue)
Connect the transmitter and the receiver in accordance with the
following the chart:
TRANSMITTER
L6
L8
BLUE CABLE
L9
BLACK CABLE
L10
L11
BROWN CABLE
After having made all the connections, supply power to the
control unit and adjust the power by means of the trimmer on
the control unit until reached the optimal working of the safety
edge.

CLOCK FUNCTION

During the automatic operating logic, when the control unit is in
pause phase each time that the contact between the START ter-
minal (L1) and the COMMON (L3) closes, the timer of the auto-
matic re-closure is restarted.
If the contact keeps closed, the timer is stopped until the contact
opens again. It is possible to connect the start terminal to a timer
in order to programme the opening and closing hours of the door.

MODELS WITH PUSH-BUTTON PANEL

The control unit EASY is produced in special models equipped
with a push-button panel on the top of the box.
The model with a 3-button push-button
panel controls the control unit with
function logic UP/DOWN.
The buttons work in parallel to the controls on the terminal
board. These are all on, included the STOP one, that, if not used,
has to be connected by a jumper with the common.
The models with push-button panel allow to activate the
automation in DEAD MAN mode in case of malfunctioning of the
safety devices.
Keeping pressed the button of the push-button panel, after 5
seconds the automation is activated ignoring the safety devices;
the motor stops immediately as soon as the button is released.
RECEIVER
BLACK CABLE
BLUE CABLE
BROWN CABLE

TECHNICAL SPECIFICATIONS

Power supply
Max motors load
Max accessories load 24V
Working temperature
Protection fuse
Dimensions
Weight
Protection
11
230VAC - 50/60 Hz (EASY)
120VAC - 50/60Hz (EASY-120V)
1100W (EASY)
600W (EASY-120V)
3W
-20°C / +60°C
F1 = 5A
170 x 185 x 70 mm
800g
IP55

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Easy-120v

Tabla de contenido