Kohler K-13462 Manual De Usuario página 12

Ocultar thumbs Ver también para K-13462:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Troubleshooting (cont.)
Symptoms
Probable
Causes
3.
Constant
A. Filter is
water flow.
plugged.
B. Diaphragm
seal is
damaged or
dirty.
C. Solenoid is
not working.
4.
Sporadic
A. The faucet
water flow.
is angled
incorrectly to
deck or
misaligned
with user area.
B. The wires
are pinched or
damaged.
5.
Sensor
A. Low
flashes once
voltage.
approximately
every 2
seconds. The
product
continues to
operate.
6.
Sensor
A. Low
flashes once
voltage.
approximately
every 2
seconds. The
product does
not operate.
1124215-2-B
Recommended Action
A. Clean or replace the filter.
B. If the diaphragm is cut or torn,
order a new diaphragm assembly.
Clean or replace the diaphragm.
C. Order and install a new solenoid
assembly.
A. Verify that the faucet is mounted
according to the installation
directions. Ensure that the faucet is
installed in a position that is above
the rim of the sink.
B. Remove the spout and verify
that the wires are tucked inside the
spout before reassembling.
A. Replace the power supply.
A. Replace the power supply.
12
Kohler Co.

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

K-13463K-13468K-13469K-13474K-13475