SPECIFICATIONS

Model:
MH165FAET
Heat­Output­BTU/WATTS 5118/1500
Airflow­(CFM)
200
Electrical­Supply
120Vac
Thermostat
32°F­-­185°F
Power­Cord
6'­POWER­CABLE­INCLUDED 6'­POWER­CABLE­INCLUDED
Dimensions:­(L"xW"xH")
13.18"x12.2"x13.97" 14.37"x13.77"x16.14"
Weight­(lbs.)
9.6­LBS.
Clearance to Combustibles
Outlet­(M)
6'­(1.8M)
Rear­(M)
2'­(.6M)
Top­(M)
2'­(.6M)
Bottom­(M)
Use­only­on­non-combustible­flooring

Assembly

•­
Remove­the­heater­and­all­of­the­packaging­material­from­
the­box.
•­
Check­all­of­the­packing­material­for­loose­parts­and­set­
aside.
•­
Thoroughly­inspect­the­heater­for­damage.­If­any­is­found­
do­not­contact­the­place­of­purchase.­Please­call­the­
Manufacturer­at­800-251-0001.
Operational Information
The­Mr.­Heater­Electric­forced­air­heaters­are­designed­to­be­
used­by­professionals.
Heat­is­created­by­electric­current­passing­through­coiled­metal
elements­bringing­them­up­to­very­high­temperatures.­The­fan­then­
passes­room­air­over­the­hot­elements­­exchanging­cold­air­for­warm.
The­air­moving­over­the­coils­keeps­them­from­reaching­
temperatures­that­are­not­safe­for­the­normal­operation­of­
the­heater.­However­it­is­important­to­keep­all­combustible­
materials­and­any­objects­that­may­be­sucked­into­the­fan­
blades­at­a­safe­distance­(please­refer­to­the­specification­table­
for­appropriate­clearances).­Make­sure­that­the­fan­blades­
remain­unobstructed­at­all­times.­Keep­unit­clean­and­dust­free.­
Do­not­block­unit­intake­or­exhaust­at­any­time.
These­units­are­designed­to­be­used­only­with­the­cord­and­
plug supplied­with­the­unit.­Do­not­use­any­plug­other­than­the­
one­supplied­by­the­manufacturer.­For­information­on­which­
receptacle­is­appropriate,­Refer­to­Figure­1­and­find­the­diagram­
that­corresponds­to­your­heater.
If­damage­has­occurred­please­refer­to­the­parts­listing­in­this­
manual­and­contact­the­manufacturer­for­a­replacement.
WARNING:­Outlet­must­be­properly­grounded,­failure­to­do­
so­may­result­in­electric­shock­or­property­damage.­
WARNING: Always­plug­heaters­directly­into­a­wall­outlet/
receptacle.­Never­use­with­an­extension­cord­or­re-locatable­
power­tap­(outlet/power­strip).
Starting Instructions
1.­­ P lace­the­heater­on­a­stable­and­level­surface.­Insure­clearance­to­
combustibles­are­observed­(See­clearances­in­the­specification­table).
2.­Turn­thermostat­counter-clockwise­to­lowest­setting.
3.­Plug­the­heater­into­a­properly­grounded­outlet.
4­­ R otate­the­power­knob­to­the­heating­position.­These­units­are­
equipped­with­a­fan­only­option­for­circulating­air.­For­heating­be­
sure­to­rotate­the­knob­to­the­appropriate­setting.
Mr. Heater Forced-Air Electric Construction Heater
MH360FAET
Figure­1
12286/3600
325
240Vac
32°F­-­185°F
12­LBS.
6'­(1.8M)
2'­(.6M)
2'­(.6M)
3
Operating Instructions and Owner's Manual
5.­­ T urn­thermostat­knob­up­(clockwise)­to­the­desired­setting.
6.­­ T he­Heating­element­and­fan­will­remain­on­until­the­temperature­
setting­is­reached.­The­unit­will­cycle­on­and­off­as­needed.
MH165FAET
NEMA­5-15R
To Stop Heating
1.­Rotate­the­thermostat­knob­to­the­lowest­position.
2.­Flip­the­power­switch­into­the­"off"­position.
3.­Disconnect­plug­from­power­supply.
NOTE:­This­heater­is­equipped­with­an­overheat­limit­switch­
which­may­cause­the­heater­to­stop.­This­is­indicated­by­a­visual­
alarm­when­the­power­switch­is­in­the­"ON"­position­and­the­
"fault"­light­comes­on.­Check­and­remove­the­cause­of­the­
overheating­before­restarting.­This­can­take­up­to­10­minuets­to­
cool­before­it­can­be­restarted.

Maintenance

WARNING:
Never­attempt­to­service­the­heater­while­the­unit­is­hot,­
In­use,­or­plugged­in.­Only­qualified­service­technicians­
should­service­these­units.
•­Thoroughly­inspect­the­unit­prior­to­use.
•­Keep­heater­clean­and­free­of­dust­and­debris.
•­­ T he­use­of­an­air­compressor­can­be­used­to­blow­out­the­dust­
from­the­heater­case.­Be­sure­to­only­use­moderate­air­pressure­
as­to­not­damage­any­internal­components.
•­­ A ­soft­dry­cloth­should­be­used­for­cleaning­of­outer­shell­
and­handle.
•­The­fan­motor­is­sealed­and­does­not­need­to­be­lubricated.
Storage
When­not­in­use,­the­heater­must­be­disconnected­from­power­
source,­dusted­off­and­the­cord­should­be­loosely­wound­
around­the­handle.
For service :
Please­call­Toll-Free­800-251-0001­www.mrheater.com
Our­office­hours­are­8:00­AM­–­5:00­PM,­EST,­Monday­through­
Friday.­Please­include­the­model­number,­date­of­purchase,­and­
description­of­problem­in­all­communication.
CONTROL
OVERHEAT LIGHT
THERMOSTAT KNOB
MH360FAET
NEMA­6-20R
FAN
OFF
ONLY
HEAT