1. TO PROGRAM AND CHANGE
THE USER CODE
Remove the small plastic cover on the front panel.
1.1 Insert the key into the key hole and turn it
counter-clockwise direction
1.2 Turn the doorknob clockwise direction to open
the safe.
1.3 Open the cover of the battery holder placed
at the back of the door and place the batteries
taking into consideration their polarity (4 x 1,5 V).
1.4 Press the red button behind the door while the
door is open, the yellow light will be on with a
short beep, please input the user code from 3-8
digits using any number from "0" to "9" within
30 seconds, then press "E" to confirm it.
1.5 To change the user code, please operate it as
same procedures as 1.4.
2. TO OPEN THE SAFE
2.1 Input the user code you programmed, then
press "E", the green light will be on, please turn
the knob within 5 seconds and pull out to open
the safe.
2.2 If wrong digit is input, you can press "C" to
cancel it.
2.3 Note: Each press the yellow light will flash with
a short beep, indicating that micro processor
confirmed it. If the yellow light keep on flashing
with the beep means the code is wrong.
Three times' wrong code will result the micro
processor refuse to accept the input for 20
seconds, if press three times' wrong code again
will result the micro processor refuse to accept
for 5 minutes.
3. TO CLOSE THE SAFE
3.1 Close the door and turn the knob anti-clockwise.
4. HOW TO USE YOUR OVERRIDE KEYS
4.1 For your convenience, we have engineered
a manual override system for your safe, we
supplied 2pcs override keys. These keys allow
you to open the safe at all times, for example,
when the batteries are run down or when
you have forgotten your code. The keyhole is
situated behind the override cover plate (logo)
beside the knob, take off the emergency lock
cover (Domus brand), insert the override key
anti-clockwise and open the safe by turning
the knob.
5. TO REPLACE THE BATTERIES
5.1 When you input your personal code to open
the safe, if the red light is on with green light,
it means the batteries are low and you should
change the batteries. To be sure the batteries
are installed correctly. Please have a test before
you close the door. Please always use alkaline
batteries only.
6. INSTALLING THE SAFE
6.1 To reduce the risk of the safe, it can be secured
to floor, wall or in a cupboard. For your
convenience, there are four holes both in the
bottom and on the back of the safe, therefore it
can be fixed by the expansion bolts supplied.
7. WARNING
7.1 Please keep the override keys of the safe in
another safety place and do not inside the safe.
7.2 In the event the keys are lost, the code is
misplaced and the batteries are weak. Then
the supplier does not take responsibility of this
product.
7.3 Whenever the safe remains without batteries
for a long period of time, you will need to
reprogram the user code.
7.4 When installing the safe, note that the serial
number is located behind the emergency lock
cover, whenever you need to access this data
in the future.