13. Technical specifications

Test voltages
Maximum resistance reading : 10 TΩ @ 10 kV
DC Voltmeter
AC voltmeter
Over voltage protection
Current measurement
Capacitance measurement
Short circuit current
Display
Test voltages accuracy
Equipment accuracy
: 500 V - 1 kV - 5 kV - 10 kV with fast selection.
From 500 V to 10 kV selectable in 25 V, 100 V
or 500 V steps. DC, negative in relation to
grounding.
: 15 V up to 600 Vdc
Precision: ± (5% of the reading + 3 digits)
: 15 V up to 600 V r.m.s.
Precision: ± (5% of the reading + 3 digits)
: CAT III – 600 V
: 1 nA up to 1500 µA
± (10% of the reading + 3 digits)
: 50 nF up to 10 µF
50 nF up to 5 µF
30 nF up to 2 µF
30 nF up to 1 µF
30 nF up to 680 nF @ 10,000 V
Precision: ± 10% of the reading ± 3 digits
: Max. 2 mA
: Alphanumeric. It exhibits measurements both
digitally and analogically by bargraph.
: ± 3% of nominal value over a 10 GΩ resistance
: ±5% of reading between 1MΩ and 1TΩ @ 10kV
±20% of reading between 1TΩ and 10TΩ @
10kV
(For lower test voltages, the superior limit is
proportionally reduced)
±20% of the reading between 10kΩ and 100kΩ
±10% of the reading between 100kΩ and 1MΩ
34
@ 500 V
@ 1,000 V
@ 2,500 V
@ 5,000 V

Publicidad

Capítulos

Tabla de contenido
loading

Tabla de contenido