10 www.electrolux.com
2.5 Indoor unit installation
Installing the mounting plate
1.
Fit the installation plate horizontally
on structural parts of the wall with
spaces around the installation plate.
2.
If the wall is made of brick, concrete
or the like, drill five or eight 5mm
diameter holes in the wall.Insert Clip
anchor for appropriate mounting
screws.
3.
Fit the installation plate on the wall
with five or eight Self-tapping Screw
ST3.9x25.
NOTE:
• Mount the Installation Plate and drill
holes in the wall according to the wall
structure and corresponding mounting
points on the installation plate.
Type of the mounting plate
120mm or
more to wall
Left rear side
refrigerant
pipe hole Ø 65
120mm or
more to wall
Left rear side
refrigerant
pipe hole Ø 65
85
150mm or more to ceiling
Indoor unit 9000Btu/h models
100
150mm or more to ceiling
Indoor unit 1200Btu/h models
• The installation plate provided with
the machine differ from appliance to
appliance.
• Dimensions are in mm unless otherwise
stated.
2.6 Before installation
1.
Decide the correct carry-in path.
2.
Move this unit as originally packaged
as possible.
3.
If the air conditioner is installed on a
metal part of the building, it must be
electrically insulated according to the
relevant electrical code.
CAUTION!
Wear gloves during the installation of
indoor unit or outdoor unit.
88
715
95
800
Indoor unit outline
120mm or
more to wall
Right rear side
refrigerant
pipe hole Ø 65
Indoor unit outline
120mm or
more to wall
Right rear side
refrigerant
pipe hole Ø 65