Installation Of Indoor Unit - Electrolux EXM18HV1W Manual De Instalación

Ocultar thumbs Ver también para EXM18HV1W:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

3 Wrap the insulating pipe with wide vinyl tape
to prevent the shift of insulating pipe. Slant
the drain hose downward slightly for smooth
drainage of condensing water.
Vinyl tape
Outlet pipe of
indoor unit
Connected
caution
1 The insulating tube should be connected reliably
with the sleeve outside the outlet pipe.
2 The drain hose should be slanted downward
slightly, without distortion, bulge or fluctuation.
Do not block water flow
with a rise.
3 Do not put the outlet in the water.
bulge
Insulating pipe
Do not put the
hose end into
water
distortion
Flooded
step 4: installation of indoor Unit
The piping can be output from right, rear right,
left or rear left.
1 When routing the piping and wiring from the left
or right side of indoor unit, cut off the tailings
from the chassis when necessary (see figure
below).
• Cut off the tailings 1 when routing the
wiring only.
• Cut off the tailings 1 and tailings 2 when
routing both the wiring and piping.
Indoor Unit outline
2 The drain hose can be connected at two
different positions. Use the most convenient
postion and, if necessary, exchange the
position of drain cap and drain hose.
• The drain hose is connected at the
rear left side of the indoor unit when
you receive the product.
Drain hole
Drain cap
Tailing 2
Tailing 1
Connection piping
Drain hose
(connected at
Refrigerant
the rear left side)
Piping
11

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Exm24hv1w

Tabla de contenido