Symbols On Lcd - Klein Tools ET600 Manual De Instrucciones

Probador digital de resistencia de aislamiento
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

ENGLISH
OPERATIONAL UNCERTAINITY
INTRINSIC UNCERTAINITY (EN61557)
Measurement
Code
Intrinsic
Insulation
A
Resistance
Earth-Bond
A
Resistance
*Indicates maximun amout allowable by standard
INFLUENCE VARIABLES AND UNCERTAINTIES (EN61557)
Code
Variable
E1
Position
E2
Supply voltage
E3
Temperature
To ensure safe operation and service of the meter, follow these instructions.
Failure to observe these warnings can result in severe injury or death.
• Before each use, verify meter operation by measuring a known voltage.
• DO NOT use the meter on a circuit with voltages that exceed the category
based rating of this meter.
• DO NOT use the meter during electrical storms or in wet weather.
• DO NOT use the meter or test leads if they appear to be damaged.
• Use ONLY with CAT IV rated test leads.
• Ensure meter leads are fully seated, and keep fingers away from the metal
probe contacts when making measurements.
• DO NOT open the meter to replace batteries while the probes are connected.
• Use caution when working with voltages above 25V AC RMS or 60V DC.
Such voltages pose a shock hazard.
• To avoid false readings that can lead to electrical shock, replace batteries
when a low battery indicator appears.
• DO NOT attempt to measure resistance or continuity on a live circuit.
• Make sure the circuit under test does not include components that can
be damaged by 1000VDC; such devices include power factor correction
capacitors, low voltage mineral insulated cables, electronic light dimmers,
and ballast/starters for fluorescent lamps.
• DO NOT perform insulation resistance testing or earth-bond resistance
testing if voltage is present on parts of an installation or equipment under
test. Circuits under test (except for voltage measurements) must be
de-energized and isolated before connections are made.
• Circuit connections must not be touched during a test. Accidental contact
with conductors could result in electrical shock.
• After insulation resistance testing, make sure the circuit is fully discharged
before removing test leads. LCD should read close to zero volts.
• Always adhere to local and national safety codes. Use personal protective
equipment to prevent shock and arc blast injury where hazardous live
conductors are exposed.
• Meter is IP40 dust & water resistant, except for the test lead jacks.
Following any contact with water, thoroughly dry meter and test lead jacks
prior to subsequent use.
4
Operating
Maximum
Uncertainty
Uncertainty*
See ELECTRICAL
<30%
SPECIFICATIONS
See ELECTRICAL
<30%
SPECIFICATIONS
% Within
Range
+/- 90°
7.21 to 9.13V
0 to 35°C
WARNINGS
AC Voltage
Resistance (Ohms)
Fuse (with rating below symbol)
Warning or Caution
To ensure safe operation and service of this meter, follow all warnings
and instructions detailed in this manual.
Risk of Electrical Shock
Improper use of this meter can lead to risk of electrical shock. Follow
all warnings and instructions detailed in this manual.
Range
<5%
Data Hold
<5%
<5%
AC (Alternating Current)
Low Battery
Maximum Value
Mega (value x 10
Volts
Test Voltage
Bar Graph
Greater Than
NOTE: The bar graph provides a visual indication of the measurement
value, showing voltage for VAC / VDC, and showing resistance for
insulation resistance testing.
SYMBOLS ON METER
DC Voltage
Audible Continuity
Double Insulated Class II

SYMBOLS ON LCD

Audible Continuity
DC (Direct Current)
Auto Power Off
Minimum Value
)
kilo (value x 10
6
Ohms
Test Lock
Negative
Zero Adjustment
)
3
5

Publicidad

Tabla de contenido
loading

Tabla de contenido