Type
Operating voltage / load voltage
CMIX current consumption
from operating voltage supply for
electronics/sensors (V
Electrical isolation
between the operating voltage
supply for the electronics/sensors
(V
) and the load voltage
EL/SEN
supply for the valves (V
Power failure bridging time
Axis string
No. of axis strings / No. of axes
Max. total length (all cables)
Type of axis connection
14
)
EL/SEN
)
VAL
CPX−CMIX−M1−1
See CPX System manual
P.BE−CPX−SYS−...
Typ. 80 ... 110 mA at 24 V,
max. 110 mA
None
10 ms (for systems with the
DGCI, a power dropout
> 1 ms causes error E80)
1 / 1
30 m
Socket M9, 5−pin
Festo CPX−CMIX−M1−1 0906NH English