Rain Bird 700 Serie Manual De Operaciones página 23

Ocultar thumbs Ver también para 700 Serie:
Tabla de contenido

Publicidad

Problem
6.
Low pressure
7.
Mechanical failure to
retract
8.
Non-rotation/ Stalling
/ Tripping
9.
Sprinkler rotates too
slowly
Rain Bird Golf Rotors Operation and Maintenance Manual
Possible Cause
Incorrect valve assembly in the
rotor
Plugged or damaged nozzle
PRS out of adjustment
PRS not holding pressure
setting
Broken valve filter screen
Blockage in tubes or case probe
Tube crimped or pinched
Debris obstructing internal
assembly screen
Inlet rock screen clogged
Debris in PRS assembly
Retract spring may be installed
with an end coil doubled over,
preventing internal retraction
Sand or rock particles may have
wedged between the bearing
guide and the riser
Stator missing, or wrong stator
installed
Debris or algae clogging the
internal assembly screen
Nozzle clogged
Inlet screen clogged
Arc was misadjusted and left in
neutral
Arc setting too small
Insufficient water pressure
Improper nozzle/stator
combination
Blinded filter screen
Correction
Check for proper valve assembly. Replace if needed.
Clean or replace nozzle.
Adjust pressure by turning adjusting screw using a screwdriver.
Replace PRS cartridge in selector.
Replace screen and clean out valve assembly.
Locate and clear blockage.
Repair or replace tube.
Clean internal assembly screen.
Remove case. Clean and reinstall rock screen.
Clean out any debris between poppet and lower stem.
Remove internal assembly and without disassembling,
compress the spring down until you free up the end coil. Reseat
the end coil and reinstall the internal assembly.
Pull the internal assembly and clean. Brush any rocks or debris
away from the head of the rotor.
Remove internal assembly. Check for proper stator.
Clean internal screen.
Clean nozzle.
Clean inlet screen. This may be difficult if debris has fallen back
down out of sight. Examine and clean thoroughly.
Turn the nozzle housing through the next trip point.
Reset arc to no less than 45 degrees.
See solutions for Problem #6 "Low Pressure."
Check for proper stator configurations and nozzle/stator
combinations. Clean as needed.
Clean as needed.
23

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

751 serie

Tabla de contenido