Determining The Location Of The Inside And Outside Unit For The S41Xx; S5Xxx, Sc41Xx & Sc5Xxx Models; D Etermining The Location Of The Exterior Unit For The S41Xx, S5Xxx, Sc41Xx - Qlima S5025 Manual De Instalación

Ocultar thumbs Ver también para S5025:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 1
G
TIP
The piping, power cable and condensation hose can be attached easier
by pulling the bottom of the interior unit about 5 cm from the wall and temporarily inserting
something so that the gap stays open, see figure 3.
f.
C onnect the coolant pipes, the power cables and the condensation hose to the interior unit. See
chapter 8.2, 9, 10 and 11.2.
g.
Position the exterior unit see chapter 5.2
h.
Connect the piping and the power cable to the exterior unit. See chapter 11.2.
i.
Vacuum the cooling unit. See chapter 12.
j.
Check the cooling circuit for leakages. See chapter 13.
.
k.
Check that the entire system is properly installed.
l.
C onnect the plug of the power supply cable to the power supply and check that the air conditioner
is working properly. See chapter 15.
Upper Hook
Lower Hook
Cushion
material
5.
DETERMINING THE LOCATION OF THE INSIDE AND OUTSIDE UNIT.

5.1 Determining the location of the inside and outside unit for the S41xx,

S5xxx, SC41xx & SC5xxx models.
Do not expose the indoor unit to heat or steam.
Select a place where there are no obstacles in front or around the unit.
M ake sure that condensation drainage can be conveniently routed away continuously going down-
wards.
Do not install near a doorway.
E nsure that the space on the left and right of the unit is more than 12cm.
U se a wire detector to detect wires and/or electric cables. to locate studs to prevent unnecessary
damage to the wall.
T he top of the indoor unit should be installed on the wall at a height of 2.3 metres or more from the
floor.
T he indoor unit should be installed allowing a minimum clearance of 15cm from the ceiling.
B e sure to level the indoor unit.
W hen determining the location of the interior unit take the possible locations of the exterior unit
into account. Interior and exterior part must be linked by piping and cables.
4
48
48
Figure 3
G
TAKE CARE
For the SC41xx & SC5xxx models: The length of the piping is 4 metres.
For the S41xx & S5xxx models: F or units with a capacity of up to 6.0 kW, the maximum pipe
length between the inside and the outside part is 20 metres. For
units with a capacity > 6.0 kW, the maximum pipe length between
the inside and the outside part is 30 metres.
For units with a capacity of up to 6.0 kW, the maximum difference
in height between the inside and the outside part is 8 metres. For
units with a capacity > 6.0 kW, the maximum difference in height
between the inside and the outside part is 20 metres.
More than 15 cm.
More than 12 cm.
2.3 m or more
5.2 Determining the location of the exterior unit for the S41xx, S5xxx,
SC41xx & SC5xxx models
I nstall the outdoor unit on a rigid base to prevent increasing noise level and vibration.
G
NOTE
The outdoor unit produces sound when in use, this could interfere with local legislation. It
is the responsibility of the user to check and to make sure the equipment is in full compliance
with local legislation.
Determine the air outlet direction where the drainaged air is not blocked.
T ake the air conditioner weight into account.
I f an awning is built over the outdoor unit to prevent direct sunlight or rain exposure, make sure that
heat radiation from the condenser is not restricted.
E nsure that the clearance around the back of the unit is more than 30 cm and left side is more than 30
cm. The front of the unit should have more than 200 cm of clearance and the connection side (right
side) should have more than 60 cm of clearance. See picture 5.
B e sure to level the outdoor unit
More than 60 cm.
LEFT
More than 30 cm.
More than 30 cm.
FRONT
More than 200 cm.
More than 60 cm.
More than 12 cm.
Figure 4
BACK
RIGHT
4
49
49