C Onnection The Condensation Drainage Hose For The S41Xx, S5Xxx, Sc41Xx; Drain Joint Installation; Electrical Work - Qlima S5025 Manual De Instalación

Ocultar thumbs Ver también para S5025:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 1
Outer
Tightening torque
Additional tightening
diam.
(N.cm)
torque (N.cm)
1500
1600
Ø 6.35
(153kgf.cm)
(163kgf.cm)
2500
2600
Ø 9.53
(255kgf.cm)
(265kgf.cm)
3500
3600
Ø 12.7
(357kgf.cm).
(367kgf.cm)
4500
4700
Ø 16.0
(459kgf.cm).
(479kgf.cm)
e.
I nsulate the connection points on the interior section with insulation material to prevent condensa-
tion build-up .
f.
W ind the piping, connection cable and drain hose, behind the interior unit, with tape so that a firm
bundle is formed. This makes it easier to mount the interior unit to the mounting plate.
Indoor unit
Ponding box
Connective cable
Pipe room
Connective pipe
Wrapping belt
Drain hose
Figure 14
G
ATTENTION
Copper lines must be insulated independently from each other.
G
ATTENTION
Always use the highest care when bending the piping. Make sure that the piping always is
bent and not buckled. In case of a buckled pipe: replace the complete piping or the buckled part,
as this is a potential refrigerant leak and may cause damage to the air conditioner.
9. CONNECTION THE CONDENSATION DRAINAGE HOSE FOR THE S41XX &
S5XXX, SC41XX, SC5XXX MODELS
9.1
Connection the condensation discharge hose to the interior unit.
Connect the included condensation drainage hose to the interior unit by sliding the hose over the hose nip-
ple on the interior unit. Ensure that the condensation drainage hose always runs downwards and do not
hang the end in the water. See fig. 15.
Always run the condensation drainage hose under the coolant pipes to prevent that the condensation tray
from overflowing.
4
56
56
CAUTION
• B e sure that the drain hose is located at the lowest side of the bundle. Locating at the upper
side can cause drain pan to overflow inside the unit.
• R un the drain hose sloped downward over the whole length to drain out the condensed water
smoothly.
Do not block water flow by a rise.
Do not put the end of drain hose
Figure 15
9.2

Drain joint installation

Fit the seal into the drain elbow, then insert the drain joint into the base pan hole in the bottom of the
outdoor unit, rotate 90° to assemble them securely. Connect the drain joint with an extension drain hose
(not included). In this way condensed water, which is produced during heating mode of the air conditioner,
can be drained away. See fig. 16.
Drain joint
Seal
Base pan hole of
outdoor unit
Figure 16

10. ELECTRICAL WORK

Connect the air conditioner to a separate group. Ensure that this group has the correct fuse
See following table.
Power voltage supplied should be in the range of 95%~105% of rated voltage on rating table.
The power supply must have an earth leak switch installed.
Ensure the air conditioner is grounded well.
C onnect the wires according the attached electrical connection diagram located on the panel of the
outdoor unit. See chapter 11
A ll wiring must comply with local and national electrical standards and codes and be installed by
qualified and skilled people.
Model
Power supply
≤ 3,5 kW
230V~50Hz
> 3,5 kW
230V~50Hz
G
NOTE!
The supply voltage should be consistent with the rated voltage of the air conditioner.
into water.
Seal
Drain pipe
.
Input Rated Current
Power cord size
(Switch/Fuse)
16A
2,5 mm
2
16A slow
2,5 mm
2
4
57
57

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

S5032S5048Sc5025Sc5032Sc5048Sc4125 ... Mostrar todo

Tabla de contenido