Note:
•
The drinking water mains valve and
the circuit breakers for the electrical
system need to be located in the most
convenient position for the operator to
access them easily and quickly.
•
The machine should be placed on a flat
counter and must be placed in settings
with the following temperatures:
Minimum room temperature: 5°C/41°F;
Maximum
room
temperature:
32°C/89°F.
•
If the machine has been temporarily
housed in settings with a room
temperature of less 0°C/32°F, the
machine must be placed in a warmer
environment in order to gradually
defrost the hydraulic system prior to
use.
•
Water pressure supply must be between
0,24 and 0,48 MPa.
12
1) Power Switch Function
The two-position power switch on the
Modbar module front panel has two
separate functions: ON and OFF.
0 - Off: In this position, the
module is in the off position.
I - Standby Mode: In this position, the module
is in standby mode. When in standby
mode, all operations function as normal,
but no power is applied to the heating
elements. This mode is used for priming
the system upon installation, and can also
be useful for some diagnostic applications.
II - Operating Mode: In this position, the
module is in operating mode. Power is
applied to the heating elements, and all
functions operate as normal.