4) Accessories
Check the package to make sure that the
following accessories are included:
•
3 stainless steel braided hoses for water
connections;
•
5 mt of reinforced plastic tubing for
drainage;
•
9 hose clamp.
In order to proceed with installation, it is
necessary that the following are available:
•
Pipes carrying drinking water with a
3/8"G (BSP) end connection; (3/8"
Compression for USA and Canada)
•
Electrical Supply according to the
specification of the steam machine
purchased:
•
Single/Three phase 220VAC - 50/60
Hz electrical connection with ground,
protected socket and approved interlock
switch
•
Single phase 200VAC - 50/60 Hz
electrical
connection
with
protected socket and approved interlock
switch
•
Waste water drain system.
5) Water test kit
In order to enable you to check if your water
supply is within the suggested ranges, La
Marzocco the machines will be equipped
with two units of a quick water test kit (see
image below) including 6 test-strips and
14
instruction cards.
The parameters that you can measure are
Total Hardness, Total Iron, Free Chlorine,
Total Chlorine, pH & Total
Chlorides.
Ideally, you should perform a test on the
ground,
water BEFORE the water treatment system
and again AFTER the water system in order
to verify if this is actually matching our
suggested ranges.
Once the test has been performed, learn
which treatment system is most appropriate
for your particular water supply by filling out
the online water calculator on our website: LA
MARZOCCO WATER CALCULATOR (http://
www.lamarzocco.com/water_calculator/).
6) Water supply connection
In order to connect the machine up to
the water mains proceed according to the
indications given in the chapter about
Installation and in compliance with any
local/national safety standards of the
location in which the machine is being
installed.
The equipment is to be installed with
adequate backflow protection to comply
with applicable federal, state, and local
codes.
To guarantee a correct and safe functioning
of the machine and to maintain an
adequate performance level and a high
quality of the beverages being brewed it
is important that the incoming water be
of a hardness greater than 7°f (70ppm,
4°d) and less than 10°f (100ppm, 6°d),
Alkalinity,
pH should be between 6.5 and 8.5 and
the quantity of chlorides be less than
50mg/l . Respecting these values allows
the machine to operate at maximum
efficiency. If these parameters are not
present, a specific filtration device should
be installed, while always adhering to the
local national standards in place regarding
potable water.
Then connect the inlet of the water filter/
softener (if present) to the drinking water
supply using one of the supplied stainless
steel braided hoses.
the filter to the main water supply, flush
Before connecting