Operation cont.

Battery Replacement

WARNINGS:
To avoid electric shock, remove the test leads
from the meter before removing the battery cover.
1. Remove the Phillips
screw(s) on the battery cover.
2. Remove the battery cover.
3. Replace batteries with two
AAA batteries.
4. Observe polarity as shown
inside battery compartment.
5. Install the battery cover
and tighten the screw(s).
WARNING:
To avoid electric shock, do not operate meter until the
battery cover is securely fastened to the meter.
WARNING:
When replacing the battery or fuses, be sure to secure
the battery compartment door firmly to maintain the waterproof and dust
proof integrity of the meter. Loose or overtightened screws, or an improperly
seated o-ring may compromise the meter's water and dust ingress protection.
+
-
-
+
11
Specifications
Accuracy is given at 65°F to 83°F (18°C to 28°C), less than 75% relative humidity
Function
Range
400.0V
AC Voltage
(40Hz to 1kHz)
600V
All AC voltage ranges are specified from 5% to 100% of range.
Function
Range
400.0V
DC Voltage
600V
Function
Range
400.0
Resistance
4.000k
40.00k
400.0k
【1】 Below 40Ω: ±(1.0% + 18)
Resolution
Accuracy ±
(% of reading + digits)
0.1V
±(1.0% +5 digits)
1V
Resolution
Accuracy ±
(% of reading + digits)
0.1V
±(1.0% +5 digits)
1V
Resolution
Accuracy ±
(% of reading + digits)
±(2.0% + 10) 【1】
0.1
1
±(2.0% + 10)
10
100
±(2.0% + 10)
12