Manual de Operación del VLT
Drive FC 300
[37]
Control word bit 12
[38]
Motor feedback error
[39]
Tracking error
[40]
Out of ref range
[41]
Below reference, low
[42]
Above ref, high
[43]
Extended PID Limit
[45]
Bus ctrl.
[46]
Bus ctrl, 1 if timeout
[47]
Bus ctrl, 0 if timeout
[51]
MCO controlled
[60]
Comparator 0
[61]
Comparator 1
[62]
Comparator 2
[63]
Comparator 3
[64]
Comparator 4
[65]
Comparator 5
[70]
Logic rule 0
[71]
Logic rule 1
[72]
Logic rule 2
[73]
Logic rule 3
[74]
Logic rule 4
[75]
Logic rule 5
[80]
SL digital output A
[81]
SL digital output B
[82]
SL digital output C
[83]
SL digital output D
[84]
SL digital output E
[85]
SL digital output F
[120]
Local ref active
[121]
Remote ref active
[122]
No alarm
[123]
Start command activ
[124]
Running reverse
[125]
Drive in hand mode
[126]
Drive in auto mode

14-22 Operation Mode

Option:
®
Automation-
Función:
Utilice este parámetro para especificar el funcionamiento normal, para realizar pruebas o para ini-
cializar todos los parámetros, salvo par. 15-03
par. 15-05
Sobretensión
. Esta función sólo está activa cuando se desconecta la alimentación y se
vuelve a conectar en el convertidor de frecuencia.
Funcion. normal
Seleccione
[0] para el funcionamiento normal del convertidor de frecuencia con el
motor en la aplicación seleccionada.
Prueba tarjeta ctrl
Seleccione
tensión de control de +10 V. Se requiere un conector de prueba con conexiones internas para esta
prueba. Proceda de la siguiente manera para la prueba de la tarjeta de control:
®
MG.33.AC.05 - VLT
es una marca registrada de Danfoss
4 Instrucciones de programación
Arranques
, par. 15-04
[1] para comprobar las entradas y salidas analógicas y digitales y la
4
Sobretemperat.
y
63