Ground loss monitor configuration
DIP-switch 5, in group A configures the functionality of the ground loss monitor. By default,
this feature is enabled from the factory.
NOTE: The wallbox will not detect a ground connection if the ground loss monitoring
functionality is disabled.
Ground Loss Monitor Enabled
Ground Loss Monitor Disabled
Group B: Scaling current
NOTE: If the wallbox does not have a CT coil attached (indicated by DIP-switch setting of
group A = 0000x), then the scaling current is the maximum static current of the station.
NOTE: If the wallbox does have a CT coil attached, which is set by DIP-switch group A,
then the scaling current is the maximum facility current per phase.
NOTE: If the static max current is set above the station rating, an error will be shown and
the wallbox will be inoperable.