Memorising a new remote control
Press the programming button PGM, the led will light up with a fixed light. Within 10 seconds, press the
button of the new remote control that you want to memorise. If the led does not remain lit with a fixed light
but starts blinking for 5s after you have pressed the PGM button, this means that the memory is full and
cannot store any more codes.
Setting the automatic closing time (TCA)
Press the programming button PGM twice, the blinking led will start to blink rapidly. The courtesy light will
blink every second until the PGM button is pressed again; if the number of blinks is less than 5, automatic
closure is disabled, whereas if it is larger than 5 the TCA is set at a number of seconds corresponding to
the number of blinks made by the courtesy light (up to a maximum of 255).
After 255 blinks, if the PGM button is not pressed the control unit automatically leaves the programming
procedure, disabling automatic closure.
Setting the threshold of intervention of the current limiter
The current limiter has 6 thresholds of sensitivity. To set the desired sensitivity, press the programming
button PGM a first time, then press the PP button; holding down the PP button, press the PGM button again
and the blinking led will go out. The courtesy light will blink every second until the PGM button is pressed
again. The set threshold of sensitivity decreases with the number of blinks made by the courtesy light:
after 1 blink there is the greatest sensitivity (that is the minimum power), after 6 blinks, if the PGM button
is not pressed again the control unit automatically leaves the programming procedure, memorising the
minimum sensitivity (that is the maximum power).
If the threshold of intervention of the current sensor is exceeded in opening, the motor stops. In closing,
if the threshold of intervention of the current sensor is exceeded the motor inverts the direction of move-
ment for 2 sec., then stops.
Setting the photocell test
Whenever this procedure is tested the setting of the photocell test varies (that is if previously the test was
switched off it is switched on, if previously the test was switched on it is switched off). To vary the setting
of the photocell test, press the programming button PGM a first time, then press the PP button (press and
release); press the PGM button again. The blinking led lights up with a fixed light, then the courtesy light
indicates the new setting of the test: 1 blink if the test is activated, 2 blinks if the test is deactivated.