Status Display - Siemens 3RW44 2 Serie Instructivo

Ocultar thumbs Ver también para 3RW44 2 Serie:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 35
3RW44 Menu Structure
Display measured value

Status Display

ESC
OK
ESC
Phase voltages
Device status
UL1N
Active parameter set
UL2N
Parameter set 1
UL3N
Parameter set 2
Phase-to-phase voltages
Parameter set 3
UL1-L2
Type of connection
UL2-L3
Unknown/faulty
UL3-L1
Star/delta
Blocking voltages
Inside delta
ULT1
Direction of rotation
ULT2
Unknown
ULT3
Clockwise
Phase currents
Counter-clockwise
IL1
Inputs
IL2
Status - Inputs
IL3
Input 1 - Action
Power
No action
Line frequency
Manual operation local
Emergency start
Supply voltage
Slow speed
Heatsink temperature
Quick stop
Motor heat build-up
Trip reset
Remaining time for tripping
Motor right PS1
Switch off standard display
Motor left PS1
Motor right PS2
Motor left PS2
Motor right PS3
Motor left PS3
Input 2 - Action [...]
Input 3 - Action [...]
Input 4 - Action [...]
Outputs
Status - Outputs
Output 1 - Action
No action
PIO output 1
PIO output 2
Input 1
Input 2
Input 3
Input 4
Run up
Bypass operation
Coasting down
On time motor
Command motor-on
DC braking contactor
Group warning
Group error
Bus error
Device error
Power on
Ready to start
Output 2 - Action [...]
Output 3 - Action [...]
Output 4 - Action [...]
Order number
Firmware information
Version
Date
Possible only in connection with slow speed
1)
18
Settings
OK
ESC
OK
Parameter set 1
Motor 1
Rated operating current Ie
Rated operating torque
Rated operating speed
Copy motor data to PS2 + 3
Starting settings
Starting mode
Voltage ramp
Voltage ramp + current limiting
Torque control
Torque control + current limiting
Direct on line
Motor heating
Start voltage
Start torque
Limiting torque
Starting time
Maximum starting time
Current limiting value
Breakaway voltage
1)
Breakaway time
Motor thermal capacity
1)
Stopping settings
Stopping mode
1)
Coasting down
Torque control
Pump stop
DC braking
Combined braking
Stopping time
Stopping torque
Dynamic braking torque
DC braking torque
Slow speed parameters
Slow speed factor right
Slow speed torque right
Slow speed factor left
Slow speed torque left
Current limit values
Minimum current limit
Maximum current limit
Parameter set 2 [...]
Parameter set 3 [...]
Inputs
Input 1 - Action
No action
Manual operation local
Emergency start
Slow speed
Quick stop
Trip Reset
Motor right PS1
1)
Motor left PS1
Motor right PS2
1)
Motor left PS2
Motor right PS3
1)
Motor left PS3
Input 2 - Action [...]
Input 3 - Action [...]
Input 4 - Action [...]
Factory
Customer
Settings
Settings
Outputs
Output 1 - Action
No action
Depends on
order number
PIO output 1
0
PIO output 2
1500
Input 1
Input 2
Input 3
Input 4
Run up
x
Operation / bypass
Coasting down
On time motor
Command motor-on
DC braking contactor
30 %
Group warning
10 %
Group error
150 %
Bus error
10 s
Device error
0/deactivated
Power on
400 %
Ready to start
40 %
Output 2 - Action [...]
0 ms
Output 3 - Action [...]
20 %
Motor protection
Tripping class
None
x
CLASS 5 (10a)
CLASS 10
CLASS 15
CLASS 20
CLASS 30
10 s
Current asymmetry limit value
10 %
Prewarning limit tripping reserve
50 %
Prewarning limit motor heat build-up
50 %
Idle time
Pre-charge time
7
Protection against voltage failure
50 %
No
7
Yes
50 %
Temperature sensor
Deactivated
18.75 %
Thermo click
112.50 %
PTC-type A
Display settings
Language
English
Deutsch
Français
Español
Italiano
Português
Nederlands
Ελληνικά
x
Türkçe
Русский
中文
Contrast
Lighting
Brightness
Lighting on
Off with time delay
No Action
Lighting off
Trip Reset
Response to fault
Unchanged
On
Blinking
Flickering
Factory
Customer
Settings
Settings
x
No Action
No Action
x
40 %
0 s
80 %
0 s
60 s
x
x
x
50 %
x
x
3ZX1012-0RW44-0AA0