9. Wall Control Installation
3-WAY INSTALLATION
(One fan controlled by two different SW605 wall
controls) (See Figures 33 and 34.)
WARNING
!
Turning off wall switch is not sufficient. To avoid possible
electrical shock, be sure electricity is turned off at the
main fuse or circuit breaker box before wiring. All wiring
must be in accordance with National and Local codes
and the ceiling fan must be properly grounded as a
precaution against possible electrical shock.
9.9
Disconnect electrical power to the branch circuit at the
circuit breaker or fuse box before attempting to install the
ceiling fan SW605 wall control into the outlet box.
WARNING
!
Do not connect any neutral (white) wire to this control.
Incorrect wiring will damage this control.
9.10
At all wall box locations remove faceplates and screws
from existing controls. Pull controls out from wall boxes
and determine which wall box contains the "hot" lead and
which wall box contains the "load" wire. Also, identify
traveler wires which are common to both wall boxes.
Disconnect wires from existing controls only.
Do not attempt to disconnect any wires not already
9.11
connected to existing controls.
Before installing the SW605 wall control, place the SW605
wall control in "OFF" mode by pushing "ON/OFF" switch to
9.12
the "OFF" position.
Install a SW605 wall control in the wall box containing the
"hot" wire first. Connect the black wire of the SW605 wall
control to the "hot" wire. Securely connect the wires with
9.13
wire connectors supplied.
Connect the other black wire of the SW605 wall control to
both remaining traveler wires in the wall box and secure
with wire connector supplied.
(Continued)
SW605
HOT
FAN/LIGHT
HI
LIGHT
MED
WALL
LOW
FAN OFF
CONTROL
®
EMERSON
OFF
ON
BLACK
TRAVELER
WIRE
NEUTRAL
Figure 34
22
SECOND
SW605 WALL
HI
LIGHT
MED
CONTROL
LOW
FAN OFF
PURCHASED
EMERSON
®
OFF
ON
SEPARATELY
LOAD
BLACK
GROUND
RECEIVER LOCATED
WITHIN THE MOTOR
HOUSING
ETL Model No.: CF965