Powered hand tool
Agitator brush roll
replacement
When agitator brush roll brushes are worn,
the brush roll should be replaced.
Ask for HOOVER part no. 48414088.
3-21
How to replace
Disconnect cleaner from electrical
outlet.
1. Remove tool from hose and turn it so bot-
tom faces up. Press the latches on either
side of tool and remove bottom plate (A).
3-24
C
6. With curved ends down, slide end plates
(C) of brush roll into slots (E) on tool.
3-22
A
2. Unscrew the two Philips screws and
remove belt guard (B).
3-25
E
7. Replace belt guard (B) making sure not to
pinch brush bristles in guard.
Turn agitator, making sure it rotates freely.
Replace and tighten screws.
3-23
B
C
3. Remove agitator including end plates (C)
and discard.
4. Inspect belt to ensure that it is in good
condition. If belt is cracked, gouged or bro-
ken, replace it (see following section).
5. Insert brush roll through belt and position
belt over gear teeth (D) on brush roll.
3-26
B
A
8. To replace bottom plate (A), insert the four
tabs on edge of bottom plate into slots on
front of tool.
Pivot bottom plate down and snap closed.
D
11