SAFETY ELEMENTS
It is recommended that you install additional safety elements (photocells, safety bands, etc.) to guarantee the safety of the people or other
objects that could interfere in the movement of the door.
TROUBLESHOOTING
1.- The motor does not work:
1.1. Check that the motor is connected correctly.
1.2. Check that the power voltage reaches the motor (230V AC).
1.3. Check that the condenser is connected.
2.- The motor works in one direction only:
2.1.- Check that the common switch of the motor is connected correctly.
3.- The motor has no strength:
3.1. The door has hard parts in its sweep. Remove the motor and remove said points until the door can move manually with ease.
3.2. The motor does not have sufficient oil pressure. Check the pressure.
3.3. Check that the condenser has been connected and that the capacity is correct (see label on motor).
3.4. Check that the unblocking screw is in automatic position.
4.- In case of a fault in the motor power supply cable, it must be replaced by an official technical service.
If, after carrying out all these checks and adjustments, the fault persists, contact your nearest official technical
service or distributor, providing as many details as possible about the fault.
MAINTENANCE
Regularly check the installation to detect possible signs of wear and tear, damage or imbalance.
Check the door functions perfectly.
Check the safety elements every 6 months.
Check the manual unblocking system.
CERTIFICATE OF WARRANTY
We guarantee this appliance for a period of 2 years from the date of supply.
Said guarantee is applicable to all manufacturing faults.
The installer is responsible for taking the appliance to the authorised technical services.
This warranty does not include:
.- Damage caused by incorrect installation or use of the appliance.
.- Damage caused by use for which it has not been designed.
.- Damage caused by external or atmospheric agents (lightning, floods, etc.).
.- Damage caused by handling by unauthorised personnel.
15