California Safe Drinking Water and Toxic
Enforcement Act (Proposition 65) Notice:
WARNING:
This product contains or, through ordinary use
for its intended purpose, facilitates emission of a
chemical or chemicals known to the State of
California to cause cancer and/or birth defects
or other reproductive harm. To minimize
exposure to these chemicals:
Conversion Instructions
Before You Begin
CAUTION:
Before proceeding with the conversion, shut off
the gas supply to the appliance prior to
disconnecting the electrical power.
Tools Needed:
•
7mm -or- 9/32" socket with 1/4" driver & extension
•
T-30 -or- T-27 Torx driver
•
4mm hex Allen wrench
•
Large, slotted screwdriver, 0.40" X .050" blade
•
Extra large, slotted screwdriver, 0.60" X .060" blade
•
7/8" wrench -or- 7/8" socket & drive
•
T-20 Torx driver
•
Precision screwdriver, 1/8" X .020" blade
•
Soap & water mixture -or- leak-check solution
Description
Instructions
Propane Conversion Label
®
Star
Burner Jet Orifice, 1.15mm
®
Star
Burner Jet Orifice, 1.25mm
This Propane Conversion Kit contains the quantities of
parts indicated above; however, some parts may not be
used depending upon the model of appliance being
converted to LP Gas. Refer to Table 2 for a listing of
appropriate combination of orifices to be used for each
particular model.
Table 1: Conversion Kit Contents
English 2
1. Perform the LP conversion according to the
instructions in this manual.
2. The conversion and adjustment to the burners should
be done by a certified installer or agency to ensure
proper combustion.
3. Always operate the unit according to the instructions
provided with your Range.
4. Ensure proper ventilation with an open window or use
a ventilation fan or hood when cooking with Gas.
When properly converted using the prescribed LP orifices,
the burners will operate at the following flow rates using
Propane (LP) Gas:
®
•
Star
1.15mm orifices.
•
POWERBOOST
a 1.25mm orifice.
Quantity
1
1
5
1
CAUTION:
When connecting the unit to propane gas, make
certain the propane gas tank is equipped with its
own high pressure regulator. The maximum gas
pressure to this appliance is not to exceed 14.0
inches water column from the propane gas tank
regulator.
Burners — 15,000 BTU/hr. [4.39 kW] each, using
TM
— 18,000 BTU/hr. [5.27 kW], using
WARNING:
NEVER leave the gas conversion partially
completed. If the appliance is operated while the
gas conversion is incomplete, high levels of
carbon monoxide may be emitted, or a fire or
explosion may occur.
WARNING:
If the Natural Gas orifices are left in place while
attempting to operate the appliance using
Propane (LP) Gas, at the higher pressure
setting for LP Gas, the burners will produce
large flames which may emit high levels of
carbon monoxide into the room, or a fire or
explosion may occur.