8. Installation
8.1 Selection of installation equipment
Cut out the work surface according to the sizes shown in the drawing.
For the purpose of installation and use, a minimum of 5 cm space shall be preserved around the hole.
Be sure the thickness of the work surface is at least 30mm. Please select heat-resistant and insulated
work surface material (Wood and similar fibrous or hygroscopic material shall not be used as work surface
material unless impregnated) to avoid the electrical shock and larger deformation caused by the heat
radiation from the hotplate. As shown below:
Note: The safety distance between the sides of the hob and the inner surfaces of the worktop
should be at least 3mm.
For worktop and flush installation:
L
W
E
590mm
520mm
560mm
Under any circumstances, make sure the ceramic cooker hob is well ventilated and the air inlet and outlet
are not blocked. Ensure the ceramic cooker hob is in good work state. As shown below
Note: Between the unit and an extractor hood, safety distance specified by the hood manufacturer
must be complied. Please regard to the instruction of the hood manufacturer.
F
H
D
55mm
51mm
490mm
min.
min.
A
B
594(+1/0)mm
524(+1-0)mm
14
X
P
R
50mm
5,5mm 7mm