A(mm)
Check with hood manufacturer
WARNING: Ensuring Adequate Ventilation
Make sure the ceramic hob is well ventilated and that air inlet and outlet are not blocked. In order to
avoid accidental touch with the overheating bottom of the hob, or getting unexpectable electric shock
during working, it is necessary to put an insert, fixed by screws, at a minimum distance of 10mm from
the bottom of the hob. Follow the requirements below.
There are ventilation holes around outside of the hob. YOU MUST ensure these holes
are not blocked by the worktop when you put the hob into position.
Be aware that the glue that join the plastic or wooden material to the furniture,
has to resist to temperature not below 150
paneling.
The rear wall, adjacent and surrounding surfaces must therefore be able to
withstand an temperature of 90 .
8.2 Before locating the fixing brackets
The unit should be placed on a stable, smooth surface (use the packaging). Do not apply force onto the
controls protruding from the hob.
Fix the hob on the work surface by screw four brackets on the bottom of hob (see picture) after
installation.
B(mm)
C(mm)
D
50 min.
20 min.
Air intake
E
550 x 30 mm
, to avoid the unstuck of the
15