Technical Specifications - Kärcher SC 1.020 Manual De Instrucciones

Ocultar thumbs Ver también para SC 1.020:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Troubleshooting
Often, failures have simple causes and you
can do the troubleshooting yourself using
the following overview. If you are in doubt
or if the failure is not listed here please con-
tact the authorized customer service.
DANGER
Always disconnect the mains plug and al-
low the steam cleaner to cool down before
performing any maintenance work.
Repair works may only be performed by the
authorized customer service.
Long heating-up time
Steam boiler is decalcified
 Descale the steam boiler.
No steam
No water in the steam boiler.
 Turn off the appliance.
 Refill water
Steam lever cannot be pressed
anymore
Steam switch is secured with the lock /
child-proof lock.
 Move the selector switch for the steam
volume to the front.
High water output
Steam chamber too full
 Press the steam gun until less water is
emitted.
Steam boiler is decalcified
 Descale the steam boiler.
20

Technical specifications

Power connection
Voltage
Protective class
Protection class
Performance data
Heating output
Operating pressure
max.
Heating time
Steam volume
Continuous steaming
Steam push max.
Dimensions
Boiler capacity
Weight (without acces-
sories)
Width
Length
Height
Subject to technical modifications!
– 12
EN
120-127 V
1~60 Hz
I
IPX4
1500 W
0,32 MPa
6 Minutes
g/min
50 g/min
110 g/min
1,0 l
3,1 kg
250 mm
382 mm
256 mm

Publicidad

Tabla de contenido
loading

Tabla de contenido