Before Using
Before Using for the First Time
1. Remove the exterior and interior packing.
2. Before connecting the refrigerator to the power source, let it stand upright for
approximately 4 hours. This will reduce the possibility of a malfunction in the
cooling system from improper handling during transportation.
3. Clean the interior surface with lukewarm water using a soft cloth.
Usage Note
1. This refrigerator operates on 12VDC, the actual working voltage is from 10.5-17V.
NOTE: The compressor will stop running when the voltage is lower than 10.5V.
2. This refrigerator requires 10.5-17VDC, >=15A power source for normal operating.
Direct connection with AC power source is forbidden.
3. The wire of the refrigerator and outer wire must meet the following requirement:
Wire size
The Max. Length (Feet)
14 AWG
3.2 Feet
13 AWG
8 Feet
12 AWG
13 Feet
10 AWG
20 Feet
8 AWG
33 Feet
6 AWG
50 Feet
4. A proper location and reliable grounding device is recommended to avoid electric
shock when using a converter to change the power source from AC to DC.
5. Non professionals are forbidden to dismantle the drive board of the compressor
and the control board.
5
Remarks:
•
13AWG or bigger wire is recommended to be used. 14AWG wire
is not recommended.
•
This refrigerator is not equipped with power source. Please buy
the power source in local authorized dealer.