Operating Instructions
Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described.
Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or
property damage! Retain instructions for future reference.
Description
Portable oilless air compressors are for
home and workshop use. Cleaning or
replacement of the inlet filter on all
models and draining moisture from the
air receivers are required maintenance.
Safety Guidelines
This manual contains information that is
very important to know and understand.
This information is provided for SAFETY
and to PREVENT EQUIPMENT PROBLEMS.
To help recognize this information,
observe the following symbols.
Danger indicates
an imminently
hazardous situation which, if not avoided,
will result in death or serious injury.
warning indicates
a potentially
hazardous situation which, if not avoided,
coulD result in death or serious injury.
caution indicates a
potentially
hazardous situation which, if not avoided,
MAY result in minor or moderate injury.
Notice indicates
important
information, that if not followed, MAY
cause damage to equipment.
Unpacking
When unpacking unit, inspect carefully
for any damage that may have occurred
during transit. Make sure any loose
fittings, bolts, etc., are tightened before
putting unit into service. In case of
questions, damaged or missing parts,
please call 1-800-543-6400 for customer
assistance. Have the serial number,
model number, and parts list (with
missing parts circled) before calling.
REMINDER: Keep your dated proof of purchase for warranty purposes! Attach it to this manual or file it for safekeeping.
© 2010 Campbell Hausfeld/Scott Fetzer
Oilless Compressors
DO NOT RETURN
STOP!
THE PRODUCT TO
THE RETAILER!
Record the Model No., Serial No. and
date of purchase located on the base
below the pump in the space below.
Model No.
____________________
Serial No.
____________________
Date of purchase _________________
Retain these numbers for future
reference.
General Safety
CALIFORNIA PROPOSITION 65
This product or
its power cord may
contain chemicals, including lead, known
to the State of california to cause cancer
and birth defects or other reproductive
harm. wash hands after handling.
You can
create
dust when you cut, sand,
drill or grind materials such
as wood, paint, metal,
concrete, cement, or other
masonry. This dust often contains
chemicals known to cause cancer, birth
defects, or other reproductive harm.
wear protective gear.
For parts, product & service information
visit www.chpower.com
HM7110 Series
Breathable Air warning
This compressor/pump is not
equipped and should not be
used "as is" to supply breathing
quality air. For any application of
air for human consumption, the
air compressor/pump will need
to be fitted with suitable in-line
safety and alarm equipment.
This additional equipment is
necessary to properly filter
and purify the air to meet
minimal specifications for Grade
D breathing as described in
Compressed Gas Association
Commodity Specification G
7.1 - 1966, OSHA 29 CFR 1910.
134, and/or Canadian Standards
Associations (CSA).
DISCLAIMER OF WARRANTIES
In the event the compressor is
used for the purpose of breathing
air application and proper in-line
safety and alarm equipment is
not simultaneously used, existing
warranties shall be voided, and
Campbell Hausfeld disclaims any
liability whatsoever for any loss,
personal injury or damage.
GENERAL SAFETY INFORMATION
Air compressors are utilized in a variety
of air system applications. Because air
compressors and other components
(material pump, spray gun, filters,
lubrications, hoses, etc.) used make up
a high pressure pumping system, the
following safety precautions should be
observed at all times. Only persons well
acquainted with these rules of safe
operation should be allowed to use the
air compressor.
All electrical work
should be done by a
qualified (licensed or certified)
electrician. on a properly wired circuit,
the black wires supply a voltage
potential even when the unit is off.
IN635200AV 11/10

Publicidad

Tabla de contenido
loading

Resumen de contenidos para Campbell Hausfeld HM7110 Serie

  • Página 1 REMINDER: Keep your dated proof of purchase for warranty purposes! Attach it to this manual or file it for safekeeping. © 2010 Campbell Hausfeld/Scott Fetzer IN635200AV 11/10 For parts, product & service information...
  • Página 2: Spraying Precautions

    Portable Air Compressors General Safety 22. Drain tanks of moisture after each 12. Always disconnect power source (Cont.) day’s use. If unit will not be used for before working on or near a motor, or 1. Read instruction manuals for a while, it is best to leave drain cock its connected load.
  • Página 3 HM7110 Series Assembly ✽ Wire and Terminal Guide Wire Color Terminal ASSEMbLY TOOLS REqUIRED Power cord White Line Tools (not provided) for assembly: Motor cord White Load (1) 10mm nut driver Power cord Black Line (2) adjustable wrenches Motor cord Black Load FOOT ASSEMbLY (FIGURE 1)
  • Página 4 Portable Air Compressors Installation (Cont.) MOISTURE IN COMPRESSED AIR b. Voltage supply is normal. Moisture in compressed air will form into droplets as it comes from an air c. Extension cords are of the compressor pump. When humidity is high or when a compressor is in continuous use minimum gauge specified in this for an extended period of time, this moisture will collect in the tank.
  • Página 5 HM7110 Series Operation (Cont.) ASME SAFETY VALVE PRESSURE GAUGES Do not remove or Gauge attached to regulator indicates bEFORE FIRST START-UP attempt to adjust air pressure going to hose (and any tool bREAK-IN PROCEDURE the safety valve! attached to end of hose). (Complete this procedure before using Check the safety valve by performing compressor for the first time.
  • Página 6 Portable Air Compressors Maintenance This compressor is 2. To prevent overflow, monitor the cup (Cont.) equipped with a at all times when draining. manual reset thermal overload protector DRAIN CUP VALVE OPERATION 3. When the cup is partially full or which will shut off motor if it becomes 1.
  • Página 7: Troubleshooting Chart

    HM7110 Series Troubleshooting Chart Symptom Possible Cause(s) Corrective Action Compressor will not run 1. Loss of power or overheating 1. Check for proper use of extension cord (see EXTENSION CORDS, page 3) 2. No electrical power 2. Plugged in? Check fuse/breaker or motor overload 3.
  • Página 8 2. WHO GIVES THIS WARRANTY (WARRANTOR): Campbell Hausfeld / Scott Fetzer Company, 100 Production Drive, Harrison, Ohio, 45030, Telephone: (800) 543-6400. 3. WHO RECEIVES THIS WARRANTY (PURCHASER): The original purchaser (other than for purposes of resale) of the Campbell Hausfeld compressor.
  • Página 9: Directives De Sécurité

    (oFF). produits chimiques reconnus pour causer MÉMENTO: Gardez votre preuve datée d'achat à fin de la garantie! Joignez-la à ce manuel ou classez-la dans un dossier pour plus de sécurité. IN635200AV 11/10 © 2010 Campbell Hausfeld/Scott Fetzer 9 Fr...
  • Página 10: Précautions De Pulvérisation

    Compresseurs D’Air Portatifs Généralités Sur La 10. L’installation des fils et fusibles et autres accumulations. Ceci sert à devraient suivre les codes électriques, éviter la sur-pression. Sécurité (Suite) capacité du courant, et doivent êtres Ne jamais enlever mis à la terre correctement. ou essayer d’ajuster 1.
  • Página 11: Installation Électrique

    Série HM7110 Généralités Sur La ✽ Guide de Fils et bornes Couleur borne Chaud Sécurité (Suite) Cordon d’alimentation Blanc Ligne nettoyage avec des solvants ou Cordon du moteur Blanc Charge produits chimiques toxiques. Cordon d’alimentation Noir Ligne Cordon du moteur Noir Charge 29.
  • Página 12: Instructions De Mise À La Terre

    Compresseurs D’Air Portatifs Installation (Suite) L’HUMIDITÉ DANS L’AIR COMPRIMÉ Seul un électricien L’humidité dans l’air comprimé forme des goutelettes en arrivant de la pompe du qualifié doit compresseur. Si l’humidité est élevée ou si le compresseur est utilisé continuellement, cette effectuer l’installation électrique et humidité...
  • Página 13: Avant Chaque Démarrage Procédure De Fonctionnement

    Série HM7110 6. Débrancher le cordon Functionnement Vérifier la soupape de sûreté de la d'alimentation. manière suivante : (Suite) 1. Brancher le compresseur et le faire 7. Fermer le robinet de vidange. • Régulateur - Le régulateur sert à régler fonctionner jusqu'à...
  • Página 14 Compresseurs D’Air Portatifs Functionnement ENLEVAGE, INSPECTION ET REMARqUE: Il faut vérifier et nettoyer REMPLACEMENT DU FILTRE périodiquement le filtre à air dans (Suite) le boîtier du filtre du côté de la tête Pour remplacer un filtre, enlever et plus souvent s’il est utilisé sous le couvercle du carter de filtre.
  • Página 15: Guide De Dépannage

    Série HM7110 Guide De Dépannage Symptôme Cause(s) Possible(s) Mesures Correctives Compresseur ne 1. Perte de puissance ou surchauffage 1. Vérifier l’usage correct des cordons prolongateurs fonctionne pas (voir CORDONS PROLONGATEURS, page 9) 2. Manque de puissance électrique 2. Modèle branché? Vérifier le fusible/disjoncteur ou surcharge du moteur 3.
  • Página 16: Garantie Limitée

    9. RESPONSABILITÉS DE L’ACHETEUR AUX TERMES DE CETTE GARANTIE: A. Fournir une preuve d’achat datée et un état d’entretien. B. La livraison ou expédition des compresseurs portatifs ou des pièces détachées au Centre De Service Autorisé Campbell Hausfeld. Taux de frais, si applicables, sont la responsabilité de l’acheteur.
  • Página 17 PoDRiA ocasionarle la muerte o alarma, todas la garantías se anularán No. de Serie _____________________ heridas de gravedad. y la compañía Campbell Hausfeld no Fecha de Compra _____________________ Ésto le indica que asumirá NINGUNA responsabilidad por hay una situación Guarde estos números para referencia en...
  • Página 18: Compresores De Aire Portátiles

    Compresores de Aire Portátiles 10. Las conecciones eléctricas y Generales de Seguridad 19. NUNCA modifique la válvula de fusibles deben estar conectadas a seguridad o el presostato. Evite Continuación tierra adecuadamente, seguir los la acumulación de pintura u códigos locales de electricidad y no otras substancias en la válvula de 1.
  • Página 19: Ensamblaje

    Serie HM7110 Generales de Seguridad ✽ Guía de cables y terminales Continuación Cable Color Terminal Con tensión Cordón eléctrico Blanco Línea 26. Use un respirador para rociar. Cordón del motor Blanco Tensión 27.Nunca rocíe la pintura y otros Cordón eléctrico Negro Línea Cordón del motor...
  • Página 20: Funcionamiento

    Compresores de Aire Portátiles Instalación (Continuación) HUMEDAD EN EL AIRE COMPRIMIDO La humedad que se acumula en el aire comprimido se convierte en gotas a medida ALAMbRADO que sale del cabezal del compresor de aire. Cuando el nivel de humedad es muy alto o 1.
  • Página 21: Antes De Arrancarlo Por Primera Vez Procedimiento De Ablande

    Serie HM7110 Funcionamiento ANTES DE ARRANCARLO POR Si se deja el compresor en la posición PRIMERA VEz PROCEDIMIENTO DE (Continuación) ON (encendido) y el aire sale del AbLANDE tanque al usar una boquilla para Presostato Complete este procedimiento antes de Regulador inflar neumáticos, una herramienta, usar el compresor por primera vez.
  • Página 22: Mantenimiento

    Compresores de Aire Portátiles Funcionamiento Mantenimiento (Continuación) libere toda Gire hacia la la presión y TECNOLOGíA DE INFLADO RáPIDO izquierda para desconecte la unidad antes de darle [RAPID INFLATION TECHNOLOGY™ drenar. cualquier tipo de mantenimiento. (RIT)] 1. Chequee el compresor a ver si tiene Gire la válvula Este compresor está...
  • Página 23: Almacenamiento

    Serie HM7110 Mantenimiento 3. El filtro de aire está atascado. ALMACENAMIENTO 4. La ventilación es inadecuada. 1. Mientras no lo esté usando debe (Continuación) almacenar el compresor y las Para poder Si el protector térmico apaga al mangueras en un sitio seco y frío. arrancaar de compresor con mucha frecuencia nuevo el motor, se debe dujar enfriar.
  • Página 24: Garantía Limitada

    1. DURACION: A partir de la fecha de compra por el comprador original tal como se especifica a continuación: Un Año. 2. .QUIEN OTORGA ESTA GARANTIA (EL GARANTE: Campbell Hausfeld / The Scott Fetzer Company 100 Production Drive, Harrison, Ohio 45030 Teléfono: (800) 543-6400.

Tabla de contenido