Installation - Tractel TA Serie Manual De Instalación, De Utilización Y De Mantenimiento

Placa de prueba de rotura
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 35
ceiling.
F
Fig. 4
1. Host structure
2. Anchor point
F: Traction load

4. Installation

4.1. General information
DANGER: To test an anchor point using the TA
test plate, the operator must use a manually activated
tripod loading device specifically designed and sized for
placing under traction load without risking the anchor
point to be tested (Fig. 6, page 5) or any other
apparatus placed under a load in traction of the TA test
plate especially designed and sized to be used in
complete safety.
DANGER: When installing, the installer must
ensure that all safety requirements specified in the
applicable regulations have been observed. The
installer must be equipped with all the necessary
Personal Protective Equipment to ensure safety during
the installation operations.
DANGER: It is strictly prohibited to fasten shackle
pins to the brace arms (Fig. 5, page 5).
F
1
2
A: Shackle pin
F: Force exerted by shackle pin on TA test plate.
4.2. Diagram
9
7
10
4
8
6
1. Anchor point to be tested
2. Shackle
3. Test plate
4. Securing clevis
5. Load application lever
6. Load application screw
7. Tripod legs
8. Tripod
9. Support structure
10. Securing pin
11. Shackle
12. Safety sling
13. Shackle
14. Safety anchor point
A
Fig. 5
14
13
12
F
Fig. 6
GB
F
1
2
3
11
5
5

Publicidad

Tabla de contenido