Apply the PL564 couplings to the beam (two at opposite edges if CORSA1 or RODEO1;
one at the centre and two at opposite edges if CORSA2 or RODEO2).
-
Insert the coupling in FN930 nylon cable and fasten one end with the C7039 terminal. On
the other end, in sequence, attach:
a) a PM576 support with the TB57 sliding tube.
b) A PM923 spiral cable sized according to sliding length (extension
admitted is 20% as opposed to the coiled cable).
c) Thread through the central coupling and repeat a) and b)
sequences for the second door (only for CORSA2 and
RODEO2).
-
Then insert the opposite coupling's nylon cable
and fasten with the terminal.
4
8
SPIRAL CABLE application and MOBILE DOOR mounting
SPIRAL CABLE application and MOBILE DOOR mounting
SPIRAL CABLE application and MOBILE DOOR mounting
SPIRAL CABLE application and MOBILE DOOR mounting
SPIRAL CABLE application and MOBILE DOOR mounting
13
PM576
PL564
FN930
C7039
-
Apply the door/doors' carriages as indicated in the CORSA or RODEO
technical sheets and insert the door/doors in the beam.
-
Check the sliding movement and then align and fasten the PM576
connection supports to the appropriate carriages. Verify the correct
sizing of the spiral cable, close its ends with the clamps provided and
electrically connect the ends as shown in the electric diagram on the
next page.
-
Similarly, size and connect the 2X0.50 bipolar connection cable to the
contact caps previously threaded through the door's structure.
-
Lastly, set the PM911A guide to the ground as illustrated on page 12.
TB57
PM923
4
- pg. 23 -