The junction box should be
wired as shown
Black
Electrician to
provide suitable
strain relief
Supply
White

12. Make Electrical Connections - Dedicated Circuit Models

WARNING: Risk of electric shock. To reduce the risk of electrical shock, connect the blower to a
properly installed Ground-Fault Circuit-Interrupter (GFCI). This will provide additional protection
against line-to-ground shock hazard. A 120 V, 15 A dedicated circuit is required.
WARNING: Risk of electric shock. Make sure the power has been disconnected before performing
the following procedures.
Locate and secure the supplied junction box a minimum of 1-1/2" (38 mm) above the subfloor.
The blower controls and system have been prewired at the factory. A qualified electrician should
make a routine service connection to the junction box.
Connect service to the junction box. The 60 Hz model junction box contains black and white wires
and a ground lug.
A 120 V, 15 A dedicated circuit is required. Provide a Class A Ground-Fault Circuit-Interrupter
(GFCI).
Provide a separate equipment grounding conductor for the inside ground or ground lug. The
conductor must not be connected to any current-carrying conductor.
Bond in accordance with national and local codes.

13. Install the Drain and Test Piping

CAUTION: Risk of property damage. A watertight seal must exist on all drain connections. The
watertight seal will prevent property damage.
Connect the drain to the trap according to the manufacturer's instructions.
Temporarily install the faucet handles and spout according to the manufacturer's instructions.
Turn on the hot and cold water supplies.
Check the supply connections for leakage. Repair any leaks.
Run the water to flush any debris from the lines and check the drain connections for leakage. Repair
any leaks.
Close the faucet handles.
Install the showerhead. Test it for operation and remove.
Remove the faucet handles and spout.
Sterling
Bond in accordance with
national and local codes
Ground (Green with Yellow Stripe)
Wire Connectors
From Blower Motor
From Blower Motor
Black
L1
N
White
Green with Yellow Stripe
GND
17
Blower Motor
Electrical Cord
1139487-2-F