SC230
ELECTRICAL CONNECTIONS: FASTONS
Position
Signal
1
CN2 CN3
2
CN4 CN5
ELECTRICAL CONNECTIONS: TERMINAL BOARDS
Terminal
Position
1
M1
2
3
4
M2
5
6
7
8
9
10
M3
11
12
13
14
15
16
M4
WARNING
17
18
19
20
M5
21
PROTECTION FUSES
Position
Value
F1
500 mA
F2
5 A
F3
500 mA
Description
Ground connection
Motor capacitor connection
Signal
Description
PHASE
230 Vac power supply
NEUTR
230 Vac power supply
LAMP
Flashlight output 230 Vac 40W
LAMP
Flashlight output 230 Vac 40W
COM
Motor common
OPEN
Motor connection (opening)
CLOSE
Motor connection (closing)
PED
PEDESTRIAN input (N.O.)
START
START input (N.O.)
PHOTO
PHOTOCELL input (N.C.). If not used, jumper with terminal 13
SAFETY DEVICE input (N.C.). If not used, jumper with terminal 13
SAFETY
STOP input (N.C.). If not used, jumper with terminal 13 or set dip switch 10 to ON
STOP
COM
COMMON INPUTS/OUTPUTS
GND
External accessory power supply and inductive sensor ground (blue cable)
24Vac
24 Vac external accessory power supply (photocells, radio, etc.)
24 Vac external safety device power supply present only during the operating cycle
SEC
WARNING LIGHT output 24 Vac 3W max
LIGHT
12V
Inductive sensor positive power supply (brown cable)
IMP
Inductive sensor input (black cable)
GND
ANTENNA GROUND input
ANT
ANTENNA SIGNAL input
Type
Description
FAST
Protects the ACCESSORY and SAFETY DEVICE power supply outputs
FAST
Protects the control unit at the 230 Vac power supply input
FAST
Protects the flashlight output
Slow flashing in opening, turned off in
pause, fast flashing in closing.
Slow flashing in opening, turned off fixed
in pause, fast flashing in closing.