DEFAULT SETTINGS

• DIP 1 and DIP 2 both OFF: Step-by-step with stop
• DIP 3 OFF: Pre-flashing disabled
• DIP 4 OFF: Safety device test disabled
• DIP 5 OFF: Opening photocell disabled
• DIP 6 OFF: Automatic closing disabled
• DIP 7 OFF: Deceleration disabled
• DIP 8 OFF: Fast closing disabled
• DIP 9 OFF: Motor rpm sensor disabled
• DIP 10 OFF: STOP input enabled
2
Closing limit switch
motor stop

TRIMMER ADJUSTMENT

• The trimmers TR2, TR3, TR4, TR5 can be adjusted also during gate movement and hence the effect immediately be
checked.
• The trimmer TR1 is stored only during the rest phase (gate closed).
Trimmers
Function
TR1
PAUSE
TR2
FORCE
TR3
SLOW
TR4
AMP. FORCE
TR5
AMP. SLOW
DEFAULT SETTINGS
• TRIMMER TR1 adjusted to minimum
• TRIMMERS TR2, TR3 adjusted to half position
• TRIMMERS TR4, TR5 adjusted to maximum
500 600mm
Limit switch slowing
down in closing
Description
Adjusts the PAUSE TIME from 2 to 215 seconds.
The
value is increased by turning the trimmer clockwise.
Adjusts the motor FORCE level. The force is increased by turning the trimmer clockwise.
Adjusts the DECELERATION level. Turning clockwise the gate speed/force is increased.
Adjust the motor rpm sensor sensitivity during non-decelerated motion.
Turn the trimmer clockwise to reduce sensitivity
Adjust the motor rpm sensor sensitivity during decelerated motion.
Turn the trimmer clockwise to reduce sensitivity.
Opening limit switch
motor stop
Limit switch slowing
down in opening
WARNING: With some motorizations, in function of gate's
characteristics, it could happen that with max. deceleration
the motor vibrates a little.
In this case it is necessary to adjust opportunely the
deceleration's trimmer avoiding to position it at the max.
13