FUNCTION PROGRAMMING (DIP SWITCH-SW1)
The settings are stored during the rest phase (gate closed).
DIP
Status
DIP 1
OFF
STEP-BY-STEP
DIP 2
OFF
DIP 1
ON
STEP-BY-STEP
DIP 2
OFF
DIP 1
OFF
AUTOMATIC
DIP 2
ON
DIP 1
ON
DIP 2
ON
DIP 3
ON
PRE-FLASHING
DIP 3
OFF
DIP 4
ON
SAFETY DEVICE
DIP 4
OFF
DIP 5
ON
PHOTOCELL
DURING OPENING
DIP 5
OFF
DIP 6
ON
AUTOMATIC
DIP 6
OFF
DIP 7
ON
DECELERATION
DIP 7
OFF
DIP 8
ON
FAST CLOSING
DIP 8
OFF
DIP 9
ON
MOTOR RPM
DIP 9
OFF
DIP 10
ON
STOP BUTTON
DIP 10
OFF
Function
Description
I Start pulse:
II Start pulse:
WITH STOP
III Start pulse:
IV Start pulse:
I Start pulse:
II Start pulse:
III Start pulse:
During opening it does not receive other Start commands after the first one; during
Pause subsequent Start commands reload the pause time
I Start pulse: OPENS
Subsequent Start pulses: Uninfluential
Pause from opening limit switch
Start pulse during pause: Reloads the pause time (if DIP 6 ON)
Subsequent Start pulse: OPENS
If Start button is held down:
DEAD MAN
If Pedestrian button is held down:
Enables pre-flashing of 2 seconds before motor activation during opening and closing
Disables pre-flashing
Enables the safety device TEST before activating the opening and closing cycle.
The cycle can only start if the devices work perfectly, if not, three prolonged flashes
indicate the fault.
TEST
Disables the safety device test.
When the photocell is intercepted during both opening and closing the gate
motion is locked until the photocell is freed. Subsequently, there is always an
opening phase.
Disables the photocell function during opening.
Enables automatic closing after the pause time adjustable with the trimmer TR1
PAUSE between 2 and 215 seconds.
CLOSING
Disables automatic closing.
Enables deceleration during both opening and closing when the respective limit
switch is intercepted. The deceleration speed is adjusted with the trimmer TR3
SLOW. This function provides for use of 4 magnets (see drawing 2)
Disables the deceleration function. Only 2 magnets are required (see drawing 2)
Reduces the pause time to 3 seconds after intervention of the photocells.
Disables the fast closing function.
Enables operation of the motor rpm sensor. After a reduction of the number of
motor revolutions (e.g. for an obstacle) the sensor intervenes locking the motion
and inverting the direction for 2 seconds in order to free the obstacle. At the next
SENSOR
Start pulse the motion restarts in the obstacle freeing direction.
Disables the motor rpm sensor
Disables the STOP input
DISABLE
STOP input enabled
OPENS
STOPS (will not reclose automatically)
CLOSES
OPENS
OPENS
CLOSES
OPENS
Or CLOSES (if DIP 6 OFF)
OPENS
CLOSES
SC230