Cleaning, Maintenance And Ordering Of Spare Parts; Ordering Replacement Parts - EINHELL DTA 25/2 Manual De Instrucciones Original

Ocultar thumbs Ver también para DTA 25/2:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

enough or projects, increase the operating
pressure on the pressure reducer by 0.5 bar.
Place the stapler/nailer against the test work-
piece again and fire.
Depending on results, keep changing the
operating pressure in 0.5 bar increments until
the depth that the staples or nails are driven
in is roughly correct. For precision adjustment
(Para. 7.4), use the knurled screw.
The equipment also has an automatic mode.
If you keep the trigger lever pressed, the stap-
les/nails will be shot automatically when the
pneumatic stapler/nailer is placed against the
workpiece.
To prevent faults, make sure that you do not
staple at the same point twice.
Important:
If a staple or nail becomes jammed in the
feed shaft, always immediately depressurize
the equipment first (remove the compressed
air supply hose), open the magazine shaft
and only then remove the cover plates (Fig. 8
/ Item I/J) by undoing the screws with the sup-
plied Allen keys (Fig. 2 / Item N) (Fig. 7 / 8).
Remove the jammed staples, clean the shaft
if necessary, and close again in reverse order.
6.4 Precision adjustment
The equipment has a depth setting adjuster
(Fig. 6 / Item G) in the form of a knurled screw.
If you screw it downwards (Fig. 6 / Item 1), the
staples/nails will be shot in deeper.
If you want to reduce the depth that the stap-
les/nails are shot in, you have to screw the
knurled screw upwards (Fig. 6 / Item 2).
Important: To prevent triggering unintentio-
nally, the depth setting must never be pulled
back by hand in normal operation.
7. Cleaning, maintenance and
ordering of spare parts
Important: Disconnect the equipment from the
compressed air system each time before starting
to carry out maintenance and cleaning work.
Compliance with the maintenance instructions gi-
ven here will ensure that this quality product has a
long service life and off ers failure-free operation.
Before starting work each time, check that the
magazine is securely fastened (Fig. 1/Item E).
Clean the equipment thoroughly immediately after
you have fi nished the work.
Anl_SA_DTA_25_2_SPK8.indb 18
Anl_SA_DTA_25_2_SPK8.indb 18
GB
To ensure that your stapler off ers lasting perfect
service, it requires regular lubrication. Use the
supplied oil (Fig. 2 / Item M) for this purpose.
There are two possible means of lubrication:
7.1 By mist oiler
A complete conditioning unit contains a mist oiler
and is fi tted to the compressor.
7.2 By hand
If your system has neither a conditioning unit or a
line oiler, 3-5 drops of oil have to be applied to the
compressed air connection each time before the
air tool is started up. If the air tool is not used for
several days, apply 5-10 drops of oil to the com-
pressed air connection before switching on.
Store your air tool in a dry room only.
7.3 Other maintenance work
There are no parts inside the equipment which
require additional maintenance.
7.4 Cleaning
Keep the trigger catch (Fig. 1/Item H) free
of dirt and dust as far as possible. Wipe the
equipment with a clean cloth or blow it down
with compressed air at low pressure.
We recommend that you clean the equipment
immediately after you use it.
Clean the equipment regularly with a damp
cloth and some soft soap. Do not use
cleaning agents or solvents; these may be ag-
gressive to the plastic parts in the equipment.
Ensure that no water can get into the interior
of the equipment.

7.5 Ordering replacement parts:

Please quote the following data when ordering
replacement parts:
Type of machine
Article number of the machine
Identification number of the machine
Replacement part number of the part required
- 18 -
02.11.2016 14:49:51