an authorized service centre.
POWER SUPPLY CORD REPLACEMENT
If replacement of the power supply cord is necessary, this
must be done by an authorized service centre in order to
avoid a safety hazard.
NOZZLE MAINTENANCE
See Figure 15-16
Excessive pump pressure (a pulsing sensation felt while
squeezing the trigger) may be the result of a clogged or
dirty nozzle.
■
Turn off the pressure washer and shut off the water
supply. With the surface cleaner on the ground, pull
trigger to release water pressure.
■
Disconnect surface cleaner from spray wand.
■
Remove the U-clip from the nozzle holder, then
rotate and remove the nozzle.
NOTE: Never point the spray lance at your face.
■
Using a straightened paper clip or nozzle cleaning
tool (not provided), free any foreign materials
clogging or restricting the nozzle.
■
Using a garden hose, flush debris out of nozzle by
back flushing (running the water through the nozzle
backwards or from the outside to the inside).
■
Place the nozzle back into the nozzle holder. Then
rotate the nozzle until it locks in place. Reinstall the
U-clip.
NOTE: Make sure the nozzles are securely in place
before using.
■
Reconnect the surface cleaner to the spray wand.
■
Turn on the water supply and start the pressure
washer.
English(Original instructions)