2.4 DUTY CYCLE

Spotting with simple
impulsion in AUTO mode
0.6 mm + 0.6 mm
0.8 mm + 0.8 mm
1 mm + 1 mm
1.2 mm + 1.2 mm
1.5 mm + 1.5 mm
2 mm + 2 mm
Spotting with multiple
impulsions in AUTO mode
0.6 mm + 0.6 mm
0.8 mm + 0.8 mm
1 mm + 1 mm
1.2 mm + 1.2 mm
1.5 mm + 1.5 mm
2 mm + 2 mm
Maximum welding rate without thermal activation at ambient temperature of 20°C, when in simple im-
pulsion in AUTO mode:
Spotting with simple impulsion in AUTO mode
0.6 mm + 0.6 mm
0.8 mm + 0.8 mm
1 mm + 1 mm
1.2 mm + 1.2 mm
1.5 mm + 1.5 mm
2 mm + 2 mm
ANOMALIES, CAUSES, SOLUTIONS
The welding spot does not hold:
- The power supply is faulty (low voltage, inadequate extension, faulty electrical outlet)
- Welding parameters (strength and diameter of the electrodes, welding time) are not suitable for the task being performed.
- Elements that are part of the secondary circuit (carrier arm / arm / electrode holder) are ineffective because of loose or oxidised
screws.
CONSIGNES DE SÉCURITÉ
Perform electrical installations according to the standards and the laws in place.
- Do not use cables with faulty insulation or loose connections.
- If there is visible damage to the power cord, the station must be unplugged and repaired by a professional before being used again.
- Use the spot welding station at an ambient air temperature between 5 ° C and 40 ° C and a relative humidity of 50% for
temperatures up to 40 ° C and 90% for temperatures up to 20 ° C.
- Do not use the welding machine spot in a damp or wet environment, or in the rain.
- The connection of welding cables and other interventions such as ordinary maintenance on the arms and / or electrodes must be
executed when the spot welding station is off and unplugged from the mains and in the cold state.
It is forbidden to use the equipment in environments with areas classified as hazardous due to the presence of gas, dust or vapor.
- Do not weld on containers, storage units or pipes that contain or have contained flammable liquids or gases.
- Avoid operating on materials cleaned with chlorinated solvents or in the vicinity of such products.
- Do not weld on storage units under pressure.
- Keep all flammable materials (e.g. wood, paper, rags, etc.) away from the working area .
PORTASPOT 230
Number of spots before first thermal
protection activation
139
93
60
42
26
16
Number of spots before first thermal
protection activation
50
37
30
24
19
11
Number of spots between two thermal
protection activations
Number of spots between two thermal
protection activations
"Maximum welding rate
without thermal protection activation - 20°C "
1 spot every 20 sec.
1 spot every 25 sec.
1 spot every 30 sec.
1 spot every 45 sec.
1 spot every 1 mn 10 sec.
1 spot every 2 mn 10 sec.
EN
27
23
15
10
8
4
12
9
8
7
5