Product Description - Leuze electronic MSI-EM-IO84NP Serie Instrucciones De Uso Originales

Módulo de ampliación del controlador de seguridad modular msi 400
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

2.5
Disposal
The disposal of unusable or irreparable devices should
always be done in accordance with the respectively valid
country-specific waste-elimination guidelines (e.g. European
Waste Code 16 02 14).
3

Product description

3.1
Description
The module MSI-EM-IO84NP-xx serves to extend a MSI 400
systems by up to eight unsafe inputs and up to eight unsafe
outputs.
Configuration of the module is carried out using the software
MSI.designer.
The module fulfills the following tasks:
 Forwarding the input information to the main module
 Receipt of control signals from the main module and
corresponding switching of outputs
The module MSI-EM-IO84NP-xx cannot be used on its own,
and always needs a main module, see configuration software
MSI.designer.
Simultaneous use of several MSI-EM-IO84NP-xx modules is
possible (a maximum total of twelve MSI-EM-IO84NP-xx
units in a system).
Each input/output extension module MSI-EM-IO84NP-xx
must be connected to an external power supply for the
outputs.
3.2
Display elements
Module status LED
4 input/output LEDs
(Function can be
configured)
3.2.1 Display of module status-(MS) LED
MS-LED
Off
Flashes red (1 Hz)
Flashes green (1 Hz)
Lights up green
☼☼
Flashes red/green (1 Hz)
Flashes red (2 Hz)
Lights up red
Leuze electronic GmbH + Co. KG
info@leuze.de • www.leuze.com
4 input LEDs
4 output LEDs
Meaning
Power supply voltage
below operating range
Self test, system
initialization or invalid
configuration
Module is ready for
operation
Application is carried out
Rectifiable error on output
(Y1-Y4, IY5-IY8)
Critical error (type3) in the
system, probably in this
module. Application is
stopped.
Critical system error
In der Braike 1 D-73277 Owen
Tel. +49 (0) 7021 573-0
3.2.2 Displays of input/output LEDs
Input LED (I1...I4; IY5...IY8))
Output LED (Y1...Y4;
IY5...IY8)
Off
Lights up green
Flashes green (1 Hz)
synchronously with the
red/green MS-LED
3.3
Terminal allocation
Module
4
Installing/removing
4.1
Steps for mounting the extension modules
The MSI 400 system is only suitable for
mounting in the switch cabinet with a minimum
protection class of IP 54.
WARNING
 In an MSI 400 system, the MSI 4xx base module is on the
far left, immediately followed by both optional gateways on
the right. Then followed by the extension modules.
 Make sure appropriate ESD protective measures are
maintained when mounting. Otherwise, the internal safety
bus may be damaged.
 The connection between the modules is done via the
integrated connector in the housing.
 Please note, when replacing a module, the MSI 400
modules are pushed apart approx. 10 mm before the
corresponding module can be removed from the standard
rail.
 Take the appropriate measures to prevent foreign objects
from obstructing the connector openings.
 Mount acc. to EN 50274.
 The modules are contained in a 22.5 mm wide installation
housing for 35 mm standard rails in accordance with
EN 60715.
4.1.1 Mounting the module
 Pull the latching foot outwards with a screwdriver.
We reserve the right to make changes
Meaning
Input/output is inactive
Input/output is active
Output is faulty A
rectifiable error is pending
Clamp
assignment
A1
24 V
A2
GND
I1 ... I4
Inputs 1 to 4
IY5 ... IY8
Inputs/outputs
5 to 8
(individually
configurable
with
MSI.designer)
Y1 ... Y4
Outputs 1 to 4
02/2018 – 50134615-01 – 6/22