GB
Chapter 8
8
Technical specifications
Tab. 5: Technical data of the
safe bus node UE3212
98
© SICK AG • Industrial Safety Systems • Germany • All rights reserved
Technical specifications
8.1
Data sheet
General system data
1)
Safety Integrity Level
1)
SIL claim limit
Category
1)
Performance Level
PFHd (mean probability of a
dangerous failure per hour)
T
(mission time)
M
Protection class
Enclosure rating
Power-up delay after connecting
the supply voltage
Response time of the safe bus
node UE3212
Weight
AS2Interface
Operating voltage
Power consumption
AS6Interface profile
AS6Interface master version
Data bits IN
Input channel I1 (p)
Input channel I2 (n)
Data bits OUT
LED Alarm
not used
Maximum number UE3212 per
master
1)
For detailed information on the exact design of your machine/system, please contact your local SICK
representative.
Minimum
Typical
SIL2 (IEC 61 508)
SILCL2 (EN 62 061)
Category 3 (EN ISO 13 84961)
PL d (EN ISO 13 84961)
–9
107 × 10
10 years (EN ISO 13 849)
III (EN 61 140)
IP 65 (EN 60 529)
100 g
26.5 V
S67.B.0
2.1
AS6Interface Safety at Work code sequence
on D0, D1
AS6Interface Safety at Work code sequence
on D2, D3
D0
D1, D2, D3 (don't care)
8010726/TF84/2010-07-20
Operating instructions
UE3212
Maximum
200 ms
10 ms
31.6 V
70 mA
31
Subject to change without notice