PROBLEM
The machine will not start if
you turn the key selector to
ON.
The brush does not rotate.
Aspirator does not work.
Configuration for gel batteries which are
not Sonnenschein version
-
-
Configuration for acid batteries
-
-
TROUBLESHOOTING
CAUSE
Low battery.
Damaged key block.
Main fuse blown.
Damaged battery plug.
Function card damaged.
Brush motor damaged.
Brush button damaged or
not pressed.
Function card damaged.
Intake motor damaged.
Suction unit button damaged
or not pressed.
Recovery tank full.
Blocked suction filter.
EN - 14
Professional Cleaning Machines Since 1968
Remove the cap (49) located under the
battery charger (16).
Position the switches (DP1 and DP2) as
shown in figure "B".
Remove the cap (49) located under the
battery charger (16).
Position the switches (DP1 and DP2) as
shown in figure "C".
SOLUTION
Check that the battery is
charged.
Replace.
Replace the main 30A or
75A fuse.
Replace.
Replace.
Replace.
Push the button or replace it.
Replace.
Replace.
Push the button or replace it.
Empty, wash and clean the
tank and the probes.
Clean the filter.
www.ghibliwirbel.com