Electrical supply cable (220 V)
Voltage (standard version)
Total connected load
Fuse rating
Connection cable, min. cross-sectional area
Length of mains connection cable (H05(07)RN-F)
Voltage (convertible)
Power rating
Fuse rating
Connection cable, min. cross-sectional area
Length of mains connection cable (H05(07)RN-F)
Electrical supply cable (380 V)
Voltage (standard version)
Total connected load
Fuse rating
Connection cable, min. cross-sectional area
Length of mains connection cable (H05(07)RN-F)
Voltage (convertible)
Power rating
Fuse rating
Connection cable, min. cross-sectional area
Length of mains connection cable (H05(07)RN-F)
Cold water
Maximum temperature
Max. water hardness
Minimum flow pressure
Minimum flow pressure with extended water intake
Maximum pressure
Flow rate
On-site threaded union in accordance with DIN 44991 (flat
sealing)
Length of cold water inlet hose
Length of steam condenser inlet hose
Installation plan PG 8582 CD / PG 8583 CD
PG 8582 CD
V/Hz
3 AC 220/60
kW
6,9
A
3 x 20
mm²
4 x 2,5
m
1,6
V/Hz
AC 220/60
kW
3,1
A
1 x 16
mm²
3 x 1,5
m
1,8
PG 8582 CD
V/Hz
3 AC 400/60
kW
8,5
A
3 x 16
mm²
5 x 2,5
m
1,6
V/Hz
AC 220/60
kW
3,1
A
1 x 16
mm²
3 x 1,5
m
1,8
PG 8582 CD
°C
20
mmol/l
12.6
°dH
70
kPa
200
kPa
100
kPa
1000
l/min
7.5
inches
3/4"
m
1.7
m
1.7
PG 8583 CD
3 AC 220/60
6,9
3 x 20
4 x 2,5
1,6
AC 220/60
3,1
1 x 16
3 x 1,5
1,8
PG 8583 CD
3 AC 400/60
8,5
3 x 16
5 x 2,5
1,6
AC 220/60
3,5
1 x 16
3 x 1,5
1,8
PG 8583 CD
20
12.6
70
200
100
1000
7.5
3/4"
1.7
1.7
Page 4 / 14