Production Data - Brita PURITY 450 Steam Manual

Ocultar thumbs Ver también para PURITY 450 Steam:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 90
8 Repair
Regularly check the filter system for leaks. Regularly check the hoses for kinks. Bent hoses must be
replaced.
The complete filter system must be replaced in rotation after a maximum of ten years.
The hoses must be replaced in rotation after a maximum of five years.
Caution: Prior to changing, read the Technical Data (Chapter 12) and the Operating and Safety
!
Information (Chapter 3).
Regularly clean the outside of the filter system with a soft, damp cloth.
Caution: Do not use any substances incompatible with the material (Chapter 3.4) or astringent,
!
abrasive cleaning agents.
9 Query Mode
The following data can be queried in the query mode:

Production data

Briefly press button once (< 1 second); the following message appears.
EN
Production year:
Device number:
Useful battery life: Example 31/12/19 = The battery in the display unit will be exhausted on
Total volume meter
Briefly press button twice (< 1 second); the following message appears.
00 level current data (today)
The total volume meter is managed at this level; it counts up from 0 irrespective of the cartridge
change.
32
ID Level
Serial Appliance Number
Example 08 = 2008
consecutive
31/12/19 and the complete filter system has reached its max. usage period.
00 Indicator for current level
Total volume meter
Production Year
Battery Service Life
Filter system size
Current date

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Purity 600 steamPurity 1200 steam

Tabla de contenido