8 Filter capacity
The filter capacity tables for combi ovens and conventional ovens are listed on page 5.
The bypass position can be adjusted to the local water quality or the machine type.
The following recommendations for bypass settings apply by default:
Position 0: All appliances in areas with very high water hardness.
Position 1: Combi ovens and conventional ovens with direct injection system
Position 2: Combi ovens and conventional ovens with boiler system
Position 3: All appliances in soft water areas.
You can obtain individual recommendations from your BRITA contact.
Note: The stated capacities are guide values that, depending on the product volume flow, local
water quality and machine type, may vary by ± 20%.
Note: The capacity limits refer to average use of the appliance, do not contain any filter flushing and
cleaning cycles and depend on local water quality, flow, mains pressure and flow continuity.

9 Technical data

Operating pressure
Operating/water temperature
Ambient temperature
operation
during
storage/transport
Flow rate with 1 bar pressure loss
Weight (dry/wet)
* Measuring and Display Unit

10 Order numbers

Caution: The PURITY replacement cartridge may only be used in combination with the pressure
!
vessel that has been specifically designed for its size. See page 3.
PURITY 450 Steam / PURITY 600 Steam / PURITY 1200 Steam Filter System
Article
PURITY 450 Steam Filter Cartridge
PURITY 600 Steam Filter Cartridge
PURITY 1200 Steam Filter Cartridge
Spare Parts
PURITY 450/ 600 Steam
Pressure vessel lid without a measuring and
display unit
Pressure vessel lid with a measuring and display unit
PURITY 1200 Steam
Pressure vessel lid without a measuring and
display unit
Pressure vessel lid with a measuring and display unit
Filter system PURITY Steam with filter cartridge
PURITY 450 Steam
PURITY 600 Steam
without
MDU*
MDU*
MDU*
2 bar to max. 6,9 bar
400 l/h
500 l/h
400 l/h
10 kg/12 kg
No longer available | Recommendation: Switch to a pressure
vessel lid with a measuring and display unit (1004331).
PURITY 1200 Steam
without
MDU*
MDU*
4°C to 30°C
10°C to 40°C
–20°C to 50°C
500 l/h
400 l/h
12 kg/15 kg
18 kg/24 kg
Article Number
1000653
1000252
1000231
Article Number
1004331
1001461
1004328
without
MDU*
500 l/h
EN
13

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Purity 600 steamPurity 1200 steam