Basic Operation (Front Panel)
CAUTION! Do not unplug your UPS to test its battery. This will remove safe electrical
grounding and may introduce a damaging surge into your network connections.
Results of a Self-Test: The test will last approximately 10 seconds as the UPS switches to
battery to test its load capacity and charge. All LCD icons will be illuminated and the UPS alarm
will sound.
• If the "FAULT" icon remains lit and the alarm continues to sound after the test, the battery-
supported outlets are overloaded. To clear the overload, unplug some of your equipment from
the battery-supported outlets and repeat the self-test until the "FAULT" icon is no longer lit
and the alarm is no longer sounding.
Note: The alarm beeps once per minute.
CAUTION! Any overload that is not corrected by the user immediately following a self-
test may cause the UPS to shut down and cease supplying output power in the event
of a blackout or brownout.
• If the "REPLACE" icon remains lit and the alarm continues to sound after the test, the UPS
batteries need to be recharged or replaced. Allow the UPS to recharge continuously for 24
hours, and repeat the self-test. If the icon continues to illuminate after repeated self tests,
contact Tripp Lite for service. Battery replacement should only be performed by qualified
service personnel. If the UPS requires battery replacement, Tripp Lite offers a complete line of
replacement batteries at www.tripplite.com.
Note: The alarm beeps once per minute.
3
LCD Status Screen
The LCD Status Screen indicates a variety
of UPS operational conditions. All
descriptions apply when the UPS is
plugged into an AC outlet and turned on.
Note: The LCD will illuminate for 1 second when
the UPS is plugged in, before it is turned on.
The LCD Status Screen can be rotated for easy
viewing, regardless of whether the UPS is in a
horizontal or vertical position. To rotate the LCD
Status Screen: insert a small tool in the slots on
the sides of the screen to pop it out of the UPS
housing; rotate the screen, and snap it back
into the UPS housing.
"Input Voltage" Meter: This meter measures, in real time, the AC voltage that the UPS
3a
system is receiving from the utility wall outlet. Although the Meter may occasionally display
input voltages which stray outside the range of standard computer tolerance (due to poor
quality utility service), rest assured that the UPS is designed (through the use of automatic
voltage regulation) to continuously supply connected equipment with stable, computer-grade
output voltage. In the event of a blackout (power loss), severe brownout (low power) or
overvoltage (high power), the UPS will rely on its internal battery to supply computer-grade
output voltage.
"BATTERY CAPACITY" Meter: This meter displays the approximate charge level (in 20%
3b
increments) of the UPS internal battery. During a blackout or severe brownout, the UPS will
switch to battery power, the "ON BAT" icon will be illuminated and the charge level will
deplete.
17-04-260-932663.indb 4
3a
3 g
3b
3c
3
LCD Status Screen
4
3d
3e
3f
4/25/2017 10:46:01 AM

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Agom5357Agom7082Agom5516 serieAgom5357 serieAgom7082 serie

Tabla de contenido