Basic Operation (Front Panel)
"AVR" (Automatic Voltage Regulation) Icon: This icon will illuminate whenever your UPS is
3c
automatically correcting AC line voltage without depleting battery power. This is a normal,
automatic operation of your UPS, and no action is required on your part.
"REPLACE" (Battery Recharge/Replace) Icon: This icon will illuminate and an alarm will
3d
sound after a self-test to indicate the UPS battery needs to be recharged or replaced. Allow
the UPS to recharge continuously for 24 hours, and repeat the self-test. If the icon
continues to illuminate, contact Tripp Lite for service. Battery replacement should only be
performed by qualified service personnel.
"ON BAT" (On Battery) Icon: During a severe brownout or blackout, this icon illuminates
3e
and an alarm sounds (four short beeps followed by a pause) to indicate the UPS is operating
from its internal batteries. Monitor the "Battery Capacity" Meter to determine the
approximate battery charge level available to support equipment. During a prolonged
brownout or blackout, the alarm will sound continuously (and the "BATTERY CAPACITY"
Meter will show one 20% capacity segment shaded) to indicate the UPS's batteries are
nearly out of power; you should save files and shut down your equipment immediately.
"FAULT" Icon: This icon will illuminate and an alarm will sound after a self-test to indicate
3f
the battery-supported outlets are overloaded. To clear the overload, unplug some of your
equipment from the battery-supported outlets and run the self-test until the icon is no longer
illuminated and the alarm is no longer sounding.
CAUTION! Any overload that is not corrected by the user immediately following a
self-test may cause the UPS to shut down and cease supplying output power in the
event of a blackout or brownout.
3 g
LCD Dimmer: Adjusts the brightness of the LCD Status Screen
Basic Operation (Rear Panel)
4
Surge-Only Protected
Outlets
5
Battery Backup/Surge
Protected Outlets
17-04-260-932663.indb 5
Surge-Only Protected Outlets: Provide surge and line noise
protection, not battery backup. Plug equipment that does not require
battery backup during a utility power failure (such as a printer,
scanner or fax machine) into these outlets.
Battery Backup Protected/Surge Protected Outlets: Provide both
battery backup and surge protection. Plug your computer, monitor and
other critical equipment into these outlets.
NOTE: DO NOT PLUG LASER PRINTERS INTO THESE OUTLETS.