The software of the POWER PEAK
MAXAMP LI battery charger has been revi-
sed, and is now capable of charging and
discharging up to 12 Lithium and Lithium-
Ion-Polymer cells. The new version bears
the suffix LI.
The unit is now also capable of charging
and discharging lead-acid batteries with a
nominal voltage of up to 42 Volts.
To avoid potential damage, please read
right through the operating instructions
before you attempt to use the unit for the
first time.
Introduction:
The MAXAMP LI charger features a number
of variable, freely configurable cut-off crite-
ria:
Charging:
1. Delta Peak cut-off
2. Final charge voltage cut-off
3. Temperature-controlled cut-off
Discharging:
Final discharge voltage cut-off
Parameter
CHARGE
S.CH.DELTA XXmV)
Delta Peak cut-off
S.CH.C.TEMP XX°C
Temperature cut-off
S.CH.CUT XX,xxxV
Final charge voltage
cut-off
DISCHARGE
S.DC.CUT XX,xxxV
Final discharge
voltage cut-off

Supplementary Instructions

POWER PEAK MAXAMP LI
Nicad
0...10 mV
40...45° C
approx.
1,8 V / cell
approx.
1,8 V / cell
7
The four different battery types NC, NiMH,
Lithium and Lead-acid can be charged and
discharged by setting the appropriate cut-
off criteria.
The charge process terminates automatic-
ally in accordance with the values which
have been set, and which limit value is rea-
ched first.
If you set the basic values as recommen-
ded in the table, the charge process usu-
ally terminates according to the primary
cut-off criterion (dark boxes in the table).
When dealing with lithium and lead-acid
batteries, it is particularly important to set
the correct values for cut-off voltage, as
incorrect settings will result in battery
damage.
Lithium batteries must be disconnected
from the charger as soon as possible after
the charge process has finished, as a
small residual current (10 mA) continues
to flow which could eventually overcharge
batteries of low capacity.
NiMH
Lead-acid Lithium
0 DV-setting
40...45° C
approx.
2,35 Volt x
1,8 V / cell
cell count
approx.0,9...1
1,75 Volt x
V / Zelle
cell count
Order No.
8121
(3.7 V /cell)
20 mV
20 mV
40° C
40...45° C
4,2 Volt x
cell count
3 Volt x cell
count