Protective functions:
Fans:
TX / RX output:
Dimensions:
Weight:
Charger controls
RX/TX
Banana sockets
for RX-TX battery
Output:
Crocodile clips for connection to
battery to be charged
Using the charger
·
Connect the crocodile clips to a 12 V lead-acid battery or a suitable mains PSU; take
great care over correct polarity (red = positive / black = negative).
·
The LCD screen will show „robbe"; the unit is ready to be set up.
·
Connect the battery pack to be charged to the output crocodile clips (red = positive /
black = negative). If it is not possible to connect the battery directly to the crocodile clips,
connect the crocodile clips to the battery using a charge lead, taking great care to avoid
short-circuits. If you wish to fit high-quality connectors to the output leads instead
of the crocodile clips, it is essential to connect the two thin measuring wires at
the same time.
·
The screen now displays READY (ready for use).
·
If you select temperature monitoring as the termination criterion, the temperature sen-
sor must be fixed to the battery with adhesive tape at a point which is an efficient ther-
mal conductor.
Operating instructions
POWER PEAK MAXAMP
Polarity protection at input and output, short-circuit protec
tion at output, overheating protection,
low voltage protection
2, temperature-controlled
1 ... 8 NiCD / NiMH cells, charge current approx. 250 mA
approx. 180 x 180 x 70 mm
approx. 950 g
MODE button
START/STOP button
UP/DOWN buttons
11
Order No.
8121
CURSOR buttons
Input:
Crocodile clips
for connection
to power source
Temperature
sensor